Configuring KIRK Wireless Server 600v3

14117800, Ed.2.6

Call handler specific, refer to KWS600v3 Configuration Guide for the relevant call

handler.

9

No Display of Date and Time: Enable only if time should not be displayed.

10

From the Coder Preferences, select a voice compression value that matches your

telephony infrastructure.
Contact your system administrator for more information.

11

In the Framesize fields, type the desired frame length in milliseconds and then select

either Exclusive or Silence Compression.
Contact your system administrator for more information.

Note:

If the Exclusive check box is selected for the coder, then the KWS600v3 is

forced to use the coder.

12

Click OK.

13

Click Reset (under Administration menu) to save your configuration.

7.5.5 Configuring DECT Master

On the Master page you can establish a communication protocol between the KWS600v3

and a call handler.

1

Under the Configuration menu, click DECT, and then click Master.

Figure 23

Adm. Page: Configuration/DECT/Master page

2

From the Mode list, select Active.

3

From the Protocol list, select either H323, SIP or SKINNY depending on the protocol

you are using.

4

In the GK (Gate Keeper) field, type the IP address of your call handler.
Contact your system administrator for more information.