400

STILL TIMER

0000
0001
0002
0003
0004
0005
0006
0007
0008

0.5S

5S

10S
20S
30S
40S
50S

1min
2min

For setting the time taken until the tape protection mode is established
when the unit has been left standing in the stop or still mode.
(Unit: S = seconds, min = minutes)

401

SRC PROTECT

0000
0001

STEP

HALF

For setting the tape protection mode operation when the unit has been left
standing in the still mode.
0: STEP FWD
1: STANDBY OFF (HALF LOADING)
<Note>
If STEP FWD has been selected, the unit is automatically transferred to the
STANDBY OFF (HALF LOADING) mode when the total length of time it has
been left standing in the still mode reaches 30 minutes.

403

STOP PROTECT

0000
0001

STEP

HALF

For setting the tape protection mode operation when the unit has been left
standing in the stop mode.
0: STEP FWD
1: STANDBY OFF (HALF LOADING)
<Note>
If STEP FWD has been selected, the unit is automatically transferred to the
STANDBY OFF (HALF LOADING) mode when the total length of time it has
been left standing in the still mode reaches 30 minutes.

402

DRUM STDBY

0000
0001

OFF

ON

For setting the drum operation in the STANDBY OFF (HALF LOADING)
mode.
0: The drum rotation is stopped.
1: The drum rotation is continued.

TAPE PROTECT menu

Item

Setting

No.

Superimposed

display

No.

Superimposed

display

Description of setting

The underlining indicates the factory setting.

Setup Menus

200

ID SEL

0000
0001

OTHER

DVCPRO

For setting the ID information to be returned to the controller.
0: 20 25H is returned.
1: The DVCPRO unit’s own ID (F0 33H) is returned.

INTERFACE menu

Item

Setting

No.

Superimposed

display

No.

Superimposed

display

Description of setting

The underlining indicates the factory setting.