Error Messages

Error code

Description

E — 68

This appears when there is a communication error between SERVO and AVSYS.
The data is fixed to High or Low.

Warning display

SLACK

E — 69

This appears when there is a problem in communication between SERVO and AVSYS
when the power is turned on.

SLACK

E — 6B

This appears when there is a communication error between IF and AVSYS.
There is a problem with the internal reference or external reference.

No display

E — 80

This appears when there is a problem with the supply voltage.

No display

E — 90

This appears when the backup battery has totally discharged.

No display

E — A0

This appears when there is no input of video signals or when video signals are cut off
and the mismatching detector circuit has been activated.
(The [E-A0] and the time data will be displayed alternately in the REC PAUSE mode.)

No display

E — bA

This appears when the input DC voltage has dropped to near the undercut voltage level
(approx. 10.6 V).

BATT flashes

E — 67

This appears when there is a communication error between SERVO and AVSYS.
There is a problem with the data.

SLACK

E — 65

This appears when abnormal tension has been detected.

SLACK

E — 66

This appears when the start or end processing operation fails to be completed within 7
seconds.

SLACK