background image

Copper wire size
(AWG)

Green/Yellow GND

220 V - 240 V AC Type

• Cable length and wire gauge 24 V AC Type

The recommended cable length and thickness are
shown in the table for reference. The voltage sup-
plied to the power terminals of the camera should
be between 19.5 V AC and 28 V AC.

Power Connection

Use individual power sources for the camera and
optional heater unit.

• Wire colours & functions

24 V AC Type

-11-

Connections

Cautions:

• This product should be installed and connected in conformity with local codes by qualified service personnel or

system installers.

• See page 2 for mains lead connection.
• Do not use a transformer with a capacity of more than 20 V A.
• Use a class 2 power supply.
• To prevent fire or electric shock hazard, use a UL listed cable (VW-1, style 1007) for 24 V AC connections.
• Be sure to connect the GND (grounding) lead of the camera and grounding terminal of the power supply.

Black (Live)

Blue (Neutral)

Green/Yellow (GND)

Green/Yellow (GND)

Brown (Live)

Blue (Neutral)

Brown (Live)

For optional heater

WV-NW474SE

WV-NW470S

Grey (Neutral)

BNC

BNC

Video output

Control cable

Network

Power 24 V AC

Power 220 V - 240 V AC

Adapter (supplied)

Adapter
(supplied)

To peripherals

To Video IN (CAMERA IN)

To network

Wire colour

Grey

Brown
Blue
Green/Yellow

Black

Function

24 V AC Live
24 V AC Neutral
GND

24 V AC Live
24 V AC Neutral

Note

For camera
8.6 W

For optional heater
12.1 W

#24

(0.22mm

2

)

Length
of cable
(approx.)

(m)

(ft)

#22

(0.33mm

2

)

#20

(0.52mm

2

)

#18

(0.83mm

2

)

20

30

45

75

65

100

160

260

Wire colour

Brown

Blue

Function

220 V - 240 V AC
Live

220 V - 240 V AC
Neutral

Note

9.9 W (camera)

18.9 W (with heater)

Advertising