Service level verification performance statistics – Paradyne 9788 User Manual

Page 166

Advertising
background image

7. Operation and Maintenance

7-30

December

2002

9700-A2-GB20-20

Service Level Verification Performance Statistics

The statistics in

Table 7-12, SLV Performance Statistics for Multiplexed DLCI

,

appear when Service Level Verification (SLV) is selected from the Performance
Statistics menu.

Main Menu

Status

Performance Statistics

Service Level Verification

They only appear:

For the network interface

If DLCIs are multiplexed or IP Enabled

When the Advanced SLM Feature Set is activated

Information displayed on the SLV Performance Statistics screen depends on DLCI
type. See

Table 7-12, SLV Performance Statistics for Multiplexed DLCI

or

Table 7-13, SLV Performance Statistics for IP Enabled DLCI

.

On either screen, select PrevDLCI or NextDLCI to view statistics for the previous
or next DLCI on the link. On the IP Enabled DLCI screen, select PrevPath or
NextPath to view statistics for the previous or next path associated with the DLCI.

For standard or multiplexed DLCIs, the statistics collected by the unit depend upon
the device at the far end of the connection. If the far-end device is a FrameSaver
SLV unit, frame relay, latency, and FDR/DDR performance statistics are collected.
The Frame Relay Delivery Ratio is the number of delivered frames/offered frames;
the Data Delivery Ratio is the number of delivered octets/offered octets.

If the far-end device is a non-FrameSaver device, or a FrameSaver 9120 or 9620,
only frame relay statistics are collected.

Table 7-12. SLV Performance Statistics for Multiplexed DLCI (1 of 3)

Statistic

What It Indicates

Far End Circuit

Number of the multiplexed DLCI or VPI/VCI (Virtual Path
Identifier/Virtual Channel Identifier) at the other end of the
connection.

If the far-end circuit is a DLCI, the DLCI number (16–1007)
appears. If a VPI/VCI, the number is displayed as

xx,yyy, xx being

the VPI number (0 –15) and

yyy being the VCI number (32–2047).

None

appears if the unit has not communicated with the other end.

Far End IP Addr

IP Address of the device at the other end of the multiplexed DLCI
connection.

None

appears if the FrameSaver unit has not communicated with

the other end, or if the device at the other end of the multiplexed
DLCI does not have an IP Address configured.

Dropped SLV
Responses

The number of SLV inband sample messages sent for which a
response from the far-end device has not been received.

Advertising
This manual is related to the following products: