Clearing performance statistics – Paradyne 9788 User Manual

Page 178

Advertising
background image

7. Operation and Maintenance

7-42

December

2002

9700-A2-GB20-20

Clearing Performance Statistics

Performance statistics counters can be reset to the baseline when using a
directly-connected asynchronous terminal and your security Access Level is
Level-1. This feature is useful when troubleshooting problems.

Statistic counters are not actually cleared using this feature, since true statistic
counts are always maintained to verify SLAs and to be available to view from an
SNMP NMS. Statistics viewed via the menu-driven user interface may be different
from those viewed from the NMS, because statistics can be locally cleared.

Procedure

To clear all statistics:

Main Menu

→Status→Performance Statistics →Clear All Statistics

Procedure

To clear specific sets of statistics:

To reset the SLV and DLCI performance statistic counters for the currently
displayed DLCI, use the ClrSLV&DLCIStats function key from one of the
following screens:

Main Menu

→Status→Performance Statistics→

Service Level Verification

Main Menu

→Status→Performance Statistics →DLCI

To reset frame relay link performance statistics, use the ClrLinkStats
function key.

Main Menu

→Status→Performance Statistics→Frame Relay

To reset Ethernet performance statistics, use the ClrStats function key.

Main Menu

→Status→Performance Statistics→Ethernet