Upgrading system software, Upgrading system, Software – Paradyne 9788 User Manual

Page 182

Advertising
background image

7. Operation and Maintenance

7-46

December

2002

9700-A2-GB20-20

Upgrading System Software

If you need to upgrade the FrameSaver unit’s program code, you need to
download the software into the Alternate Release directory. Upgrades can be
performed through the:

Network using a Management PVC, or

COM port, if Port Use is set to Net Link (see

Table 4-25, Communication Port

Options

)

Procedure

To download software:

1. Initiate an FTP session to the device that you are upgrading.

2. Type bin to enter binary transfer mode.

3. Type hash to enter hash mode if you want to monitor the progress of the

upgrade, provided this function is supported by your equipment.

4. Type cd system to change to the system directory.

5. Perform a put of R

xxxxxx.ocd (xxxxxx being the software release number) to

the nam.ocd file to start the upgrade.

NOTE:

During the download, a series of hash marks (#) appear. When the hash
marks stop appearing, there is a pause of about 30 seconds before the
nam.ocd: File Transfer Complete

message appears. Please be

patient. Do not exit from FTP at this time

.

See

Activating Software

on page 7-47 to activate the newly downloaded

software.

If the message displayed is . . .

Then . . .

nam.ocd: File Transfer Complete

The download was successful. The file is
loaded into system memory.

nam.ocd: File Transfer Failed –
Invalid file

The file is not valid for this FrameSaver unit.

A different R

xxxxxx.ocd file will need to be

downloaded. Repeat the step or end the FTP
session.

Advertising