Ip ping test – procedure 2, Ip ping test, Procedure 2 – Paradyne 9788 User Manual

Page 213

Advertising
background image

8. Troubleshooting

9700-A2-GB20-20

December 2002

8-29

IP Ping Test – Procedure 2

Procedure

To ping the NMS at the central site or an SNMP trap manager:

1. Verify that the central site NMS has the FrameSaver unit’s IP address in its

routing table so it can communicate with the FrameSaver unit.

2. Verify that the central site NMS’s router has the FrameSaver unit’s IP address

in its routing table so it can communicate with the FrameSaver unit.

3. Verify that the central site NMS has been configured as an SNMP Trap

Manager if the router is to route data, so a route has been configured within
the FrameSaver unit.

Main Menu

→Configuration→Management and Communication→

SNMP Traps

Or, for a local DLCI between the central site FrameSaver unit and its router,
verify that a Default IP Destination route has been configured.

Main Menu

→Configuration→Management and Communication→

Node IP

→Default IP Destination

Configure both SNMP Traps and a Default IP Destination when PVC
Multiplexing is used.

4. Select the IP Ping test.

Main Menu

→Test→IP Ping

5. Enter the IP Address of the central site NMS, then select Start.

6. Verify the results of the IP Ping test.

— While the test is running, In Progress... appears in the Status field.

— When the test is finished, Alive should appear as the Status. If any other

message is displayed, additional testing is required.