English – Nikon DX-TL4516E User Manual

Page 37

Advertising
background image

Warnings and CALL OUT output

37

ENGLISH

Warning Display

CALL OUT

output

#1

Cancelling

the warning

Log number

Countermeasure

#

#

#

LOG54 #7

LOG13 #8
LOG33 #8
LOG43 #8
LOG73 #8
LOG23 #8

LOG14 #8

LOG74 #8
LOG24 #8
LOG34 #8
LOG44 #8
LOG55 #7

LOG6200

LOG5100

LOG5200

LOG5201

LOG5300

LOG3500#5
LOG7500#6

LOG3600#5
LOG7600#6

LOG5101
LOG5102
LOG5103

Fixed

None

Fixed

None

None

Fixed

Fixed

Fixed

Fixed

Fixed

None

None

No Camera Signal

Camera signal is lost or distorted.
Please check the camera and cable
connection.

It can use as it is though a slight error
occurred.

System suspended due to unstable
processing. Recording will be resumed.
HDD was disconnected.
System suspended due to unstable
processing. Start operation again.

The recorder detected the data altered or data
recorded by other recorder.

Recorder detected technical problems
on the device.

The recorder has been rebooted. The problem
is not critical, but check the recorder.

Internal temperature is getting too high,
check the ventilation of the recorder.

Internal temperature is getting too high,
stop the operation of the recorder
immediately.

The fan of the recorder needs to be checked.

Copying data stopped because of new record
overwrites the old data.

New record will soon overwrite the old data
in copying.
Stop the recording, if you want to continue the
copying.
(NONE)

• Check whether the unit and

camera are properly connected
and turned on.

• Check whether the video signal is

being properly outputted.

• Check whether the camera with

no video signal input is set for
operation.

• Continue the operation when

there is no abnormality.

• When the error occurs

continuously, check the
HDD/media and cable and then
restart the unit.

• Restart the unit.

• Check the unit.

• Turn off the power and change

the installation condition.

• Turn off the power and change

the installation condition.

• Turn off the power and stop

using.

• Stop HDD recording to continue

copy/backup.

• Stop HDD recording to continue

copy/backup.

• Stop copy/backup to continue

HDD recording.

• Restarts by watchdog operation

or for self-recovery.

Stop recording.

Output video
signals.
Click "Clear
Warning" or press
the E button.
Automatically
clears after 1
minute.

Click "Clear
Warning" or press
the E button.

Automatically
clears after 1
minute.
Click "Clear
Warning" or press
the E button.
Click "Clear
Warning" or press
the E button.
Click "Clear
Warning" or press
the E button.
Click "Clear
Warning" or press
the E button.
Click "Clear
Warning" or press
the E button.
Lower the
temperature.
Click "Clear
Warning" or press
the E button.
Rotate the fan.
Click "Clear
Warning" or press
the E button.
Click "Clear
Warning" or press
the E button.

Regarding LOG14 : Displays during recording. The system shuts down once and then resumes recording. (The error HDD is
automatically deleted from the recording device. The recording is continued until all the registered HDDs are used up.)

Regarding LOG24 to 74: Displays during copying or playback. The playback or copy stops because the system shuts down. Carry
out playback or copy again.

Regarding LOG 54 : Displays during recording when the video signal is not existed for the camera being recorded for 2 seconds
or more. This warning may not be displayed for the recording of which recording time is less than 2 seconds.

Advertising