NuTone VS-67WH User Manual

Timer switches, Read and save these installation instructions

Advertising
background image

READ AND SAVE THESE

INSTALLATION INSTRUCTIONS!

Timer Switches

MODELS: VS-66WH, VS-67WH,

VS-68WH & VS-69WH

Timer w/Single Rocker Switch

Timer w/Double Rocker Switch

Timer w/Single Rocker Switch

1. The timer assembly is designed to mount in a 2-1/2" deep double gang box.

2. Run house power wiring (with ground) from fuse or circuit breaker box and wiring

from ventilation fan (refer to Fan motor plate for wiring instructions to motor) to
timer and switch in outlet box and make connections as illustrated in Figure 1.

3. Strip wires approximately 1/2" to make connections. Connect wire to terminal

screws in the timer side. NOTE: Use LINE-1/LOAD-1 for standard operation.
LINE-2/LOAD-2 will turn the current on at the end of timing period.

4. Insert wired switch in wall box with screws provided.

5. Insert wired timer into wall box with “TOP” (indicated on front cover) in proper

position. Refer to Figure 2.

6. Fasten timer to wall box using (2) screws provided.

7. Fasten wall plate to timer using (4) screws provided with the plate. The screws

must be self-tapped into the timer body and will require a gentle inward pressure
while firmly turning the screw.

8. Position small plastic timer dial so that “OFF” is in the up position. Install hex nut

and tighten.

9. Push knob on shaft with the tail facing down.

Timer Operating Instructions:

1. Turn knob clockwise (to the right) to desired time period. Timer will automatically

turn “OFF” at the end of period.

2. Regardless of time period desired, knob must be first rotated past “TURN PAST”

as indicated on timer dial. It may then be turned back to a shorter period if desired.

Do not supply house power until installation is
complete.

All wiring must comply with local electrical codes and
the switch must be properly grounded.

TO NUTONE UNIT

“OFF”

POSITION

TOP

WHITE

(NEUTRAL)

BLACK (HOT)

BLACK (HOT)

GROUND

GREEN

GROUND

SCREW

WHITE

(NEUTRAL)

BLACK (HOT)

EAR

TH

GROUND

(GREEN)

QUICKWIRE

CONNECTIONS

WHITE

(NEUTRAL)

BLACK (HOT)

BLACK (HOT)

BLACK (HOT)

GROUND

WHITE

(NEUTRAL)

BLACK (HOT)

EAR

TH

GROUND

(GREEN)

QUICKWIRE

CONNECTIONS

TO NUTONE UNIT

FIGURE 1

FIGURE 2

FIGURE 3

Advertising
This manual is related to the following products: