Ruud PH20V50F User Manual

Pacemaker, 4 more years, Ruud guardian system features

Advertising
background image

These units are designed to meet or exceed ANSI
(American National Standards Institute) requirements and
have been tested according to D.O.E. test procedures and
meet or exceed the energy efficiency requirements of
NAECA, ASHRAE standard 90, ICC Code and all state
energy efficiency performance criteria for energy
consuming appliances.

Before purchasing this appliance, read important energy
cost and efficiency information available from your supplier.

E

G

B

A

C

F

H

HOT

WATER

CONNECTION

H

COLD

WATER

CONNECTION

D

1/2"

3/4" N.P.T.

RELIEF

VALVE

OPENING

FLUE

ANODE ROD

Pacemaker

®

Gas Water Heaters

Available in 29, 38, 40 and 50 Gallon Tall – 30, 40 and 50 Gallon Short Gas Models

6-Year Limited Tank and Parts Warranty*
With ProtectionPlus

the 6-Year Limited Tank Warranty Becomes 10 Years!

Guardian System

• One-of-a-kind air/fuel shut-off device offers double

protection

• Maintenance free – no filter to clean
• Standard replacement parts
Environmentally Friendly Burner
• Low NOx design for low nitrous oxide emissions
Self-Cleaning
• EverKleen

patented system fights sediment build-up

• Reduces fuel costs
• Provides more hot water
Easy to Light
• No matches required
Energy Efficient
• More hot water at low operating cost
Longer Life
• Patented magnesium anode rod design incorporates a

special resistor that protects the tank from rust

High Altitude Compliant
• All models are certified for applications up to 6,000

feet above sea level. Some models are certified up to
10,200 feet above sea level. Check factory for listings

Plus…
• Brass drain valve and temperature and pressure relief

valve are included

• Meets or exceeds National Appliance Energy

Conservation Act (NAECA) requirements

Ruud Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.ruud.com

P R I N T E D I N U . S . A

0 7 / 0 8 W P

F O R M N O . 1 0 1 R - 6 R e v. 1 1

In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.

Get

4 MORE YEARS

with ProtectionPlus

Ruud Guardian System Features…

Flame Arrestor Plate

A specially-designed flame arrestor
prevents ignition of vapors outside the
combustion chamber.

Maintenance Free

Superior air filtration prevents the
flame arrestor from becoming clogged
by lint, dust and oil.

Exclusive Combustion
Shut-off System

Should a spill incident occur, the Guardian
System shuts off the gas supply and the air
supply preventing a sustained vapor burn in
the combustion chamber.

H
E

High Efficiency Models Feature:

High performance and lower operating cost

Compliant with many gas utility incentive programs

*See Residential Warranty Information Brochure

for complete warranty information.

SPECIFY LP GAS WHEN ORDERING. Add “P” suffix to the model number. Example: PH2R40-40PF.
• For SCAQMD rule 1121 compliance models (California only), add “SQ” suffix to the model number. Example: PH2R40-40FSQ.

DESCRIPTION

FEATURES

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

ENERGY INFO.

HT. TO

WATER

HT. TO

GAS INPUT IN

RECOVERY IN

FIRST HOUR

HT. TO

TANK

GAS

VENT

CONN.

SIDE

WATER

SHIP.

ENERGY

AVG. ANN.

GAL.

THOUS. BTU/HR.

G.P.H. 90° RISE

DEL. G.P.H.

VENT

HT.

DIAM.

CONN.

SIZE

CNTR.

T&P

CONN.

WT.

FACTOR

OPER. COST

CAP.

MODEL NUMBER

NAT.

LP

NAT.

LP

NAT.

A

B

C

D

E

F

G

H

(LBS)

NAT.

NAT.

40

PH2R40-40F

40

34

40.4

34.3

68

63-1/4

59-3/4

21

14-1/2

3

8

53-1/2

3/4

135

0.62

$294

50

PH2R50-40F

40

36

40.4

36.4

83

62-1/4

58-3/4

23

14-1/2

3

8

52-1/2

3/4

165

0.62

$294

29

P2-30F

32

30

32.3

30.3

50

59-3/4

56-3/8

16-1/8

14-1/2

3

8

50-3/4

3/4

100

0.62

$294

40

P40-36F1

36

36.4

67

61-1/2

58

17-3/4

14-1/2

3

8

53

3/4

120

0.59

$309

40

P2-40F1

38

32

38.4

32.3

73

61-3/4

58-3/8

18-1/8

14-1/2

3

8

52-1/4

3/4

120

0.59

$309

38

PH2-40F

40

34

40.4

34.3

68

61-1/2

57-3/4

19-3/4

14-1/2

3

8

52-1/4

3/4

125

0.60

$304

50

P2-50F1

38

36

38.4

36.4

90

61-1/2

58-1/4

20-1/8

14-1/2

3

8

51-3/8

3/4

130

0.58

$315

50

PH2-50-40F

40

36

40.4

36.4

83

61-1/2

58

21-3/4

14-1/2

3

8

52-1/2

3/4

150

0.58

$315

50

PH2-50-50F

50

50.5

83

62

58

21-3/4

14-1/2

4

8

52-1/2

3/4

150

0.58

$315

30

P2-30S-30F

30

30.3

50

49-3/4

46-1/4

19-3/4

14-1/2

3

8

40-1/4

3/4

98

0.61

$299

40

P2-40SF

36

34

36.4

34.3

72

52-3/4

49-3/8

20-1/8

14-1/2

3

8

42-3/4

3/4

130

0.59

$309

40

PH2-40SF

40

36

40.4

36.4

72

53-7/8

50-1/2

20-1/8

14-1/2

3

8

44

3/4

130

0.59

$309

50

PH50SF

40

36

40.4

36.4

84

54-1/4

49-3/4

22-1/4

14-1/2

3

8

44

3/4

158

0.59

$309

T
Y
P
E

T
A
L
L

H
E

TALL

S
H

O
R

T

6

Y E A R L I M I T E D

TANK WARRANTY

B E C O M E S

10

For more details, see form 101-7.

Energy Factor and Average Annual Operating
Costs based on D.O.E. (Department of Energy)
test procedures. D.O.E. national average fuel rate
natural gas $1.218/therm; LP $1.87/gallon

.

®

Advertising
This manual is related to the following products: