Data output, Data conversion – Raymarine Radar equipment Raychart Chartplotter RC530 PLUS User Manual

Page 208

Advertising
background image

8-30

hsb

2

PLUS Series Color LCD Display

Data Ou

tpu
t

Data Output

Data is transmitted in SeaTalk and NMEA formats as detailed in Appendix D
and can be used to enhance other equipment as required. You can disable the
transmission of individual NMEA output sentences - refer to NMEA Out Set
Up
on page 7-9.

The SeaTalk input/output connection is detailed in SeaTalk Connection on
page 8-27.

The NMEA output connector is a 4-pin connector as illustrated below. The
1.5 m NMEA OUT cable has a ferrite clamp attached to ensure EMC
conformance.

Figure 8-19: NMEA Output Connector

Data Conversion

The

hsb

2

series displays convert some information across the communications

links as follows:

NMEA In to NMEA Out and SeaTalk
SeaTalk to NMEA Out

This enables data received by the display to be passed to other instruments. For
example, if you have a master and a repeater display, you only need to connect
NMEA In to the master display, which will pass the data to the repeater via
SeaTalk.

You can prevent NMEA heading data being bridged onto the Seatalk bus -
refer to Bridge NMEA Heading on page 7-8.

Note: To transfer NMEA data, or to convert the data, the display must be pow-
ered On.

Pin 2, white
Pin 5, screen

Pin 3, blue
Pin 4, not connected

*Pin 1 does not exist on this connector

NMEA OUT connector

NMEA OUT connector
Pin Pin name Function

2 NMEA_GND NMEA ground

3 NMEA_SIG NMEA data output

4 N/C N/C

5 CGND Screen

2

4

5

3

Rear of display

NMEA out

D4254_1

Advertising