Raypak HI DELTA 1802B User Manual

Hi delta, Type p

Advertising
background image

Catalog No.: 6000.342D

Effective: 9-01-09

Replaces: 6-22-08

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

MBTUH Input:


Sealed Combustion Chamber
100% Factory Fire Tested
Efficiency: 85%
Minimum Non-condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-year Thermal Shock Warranty
Limited Five-year Heat Exchanger Warranty
Full Safety Diagnostics with Fault History
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Fan-assisted
Non-ferrous Bypass
Patented Burner Security Blanket


Heat Exchanger
ƒ

Brass

Headers

ƒ

ASME Inspected and Stamped

160 PSIG Working Pressure

ƒ

National Board Approved

ƒ

Cupro Nickel Finned Tubing

ƒ

ASME Steel Tube Sheet

ƒ

Silicone High Temp O-Rings

ƒ

125 PSIG ASME Pressure Relief Valve

ƒ

Temperature and Pressure Gauge

ƒ

Water

Connections

Left – Standard
Right – Option A-6

ƒ

Bronze Pump, 120V, 60Hz

ƒ

Non-ferrous Pool Bypass

Controls
ƒ

120V, 60Hz, 1

∅ Power Supply

ƒ

120/24V 60Hz Transformer

ƒ

100%

Shut-off/Lockout

ƒ

Hot Surface Ignition Systems (2)

ƒ

Remote Flame Sensors (2)

ƒ

High Limit Control, Auto Reset

ƒ

On/Off Power Switch

ƒ

Manual Shut-off, Front-mounted

ƒ

Flow

Switch

ƒ

Blocked Vent Pressure Switch

ƒ

Combustion Air Proving Switches

ƒ

Economaster Pump Time Delay

ƒ

Poolstat

ƒ

Diagnostic Panel with LCD Display

2 Lines, 20 Characters


Gas Train
ƒ

Combination

Valves

ƒ

On/Off

Firing

ƒ

Low Gas Pressure Switch, Manual

ƒ

Fuel

Natural Gas
Propane Gas

ƒ

Design Certified ANSI Z21.56/

CSA 4.7 (P models)

ƒ

Design Certified ANSI Z21.10.3/

CSA 4.3 (WHP models)

Burner
ƒ

Ultra-low

NOx:

Less than 20 PPM

Construction
ƒ

Indoor/Outdoor

Construction

ƒ

Enclosed Front Controls

Venting
ƒ

Vent

Location

Top – Standard
Rear – Option D-14

ƒ

Vent Termination Cap

Outdoor – Option D-11
Indoor, Horizontal –

Option D-15

Indoor, Vertical (by others)

ƒ

Combustion

Air

In-Line Filter Kit (TruSeal

only) – Option D-17

Air Intake Elbow –

Option D-16


Options

C-6

Ignition Module, Manual Reset

D-21 TruSeal™ Direct Vent

Right Side

Left Side (Model 1802B

Only)

F-10 Low Water Cut-off, Remote

Probe

P-__ Cold Water Run System

(See Page 3)

S-2

Dual High Gas Pressure
Switches, Manual Reset

X-1

SureRack Kit

X-2

SureRack Kit Above Grade
Add-on (used with X-1)

Y-241 Temperature Controller,

1-4 Stages

Regulatory Agency Requirements

G-1

CSD-1







Hi Delta

®

- Type P

Commercial Pool Heaters

Models 1802B-2342B

Standard “H” Bypass Shown

Patent No. 7,044,124