R98eASME (V3237W-ASME)

Type of Appliance

Rinnai model number

Operation

Minimum/Maximum Gas Rate (Input)

Electrical


Electrical Consumption



Ignition System

Hot Water Capacity

Temperature

Temperature (without controller)

Approved Gas Types

Installation

Thermal Efficiency

Service Connections



Water Flow Control

Minimum/Maximum Water Supply Pressure

Temperature controlled, continuous flow, gas hot water system

REU-V3237W-ASME

Forced combustion

19,000 - 237,000 BTU/h (Natural Gas or Propane)

Appliance:

AC 120 Volts - 60 Hz

Controller:

DC

12

Volts

Normal

72

watts

Standby 2

watts

Anti-frost protection

116 watts

Direct electronic ignition

0.6 to 8.0 GPM (50° F rise)

0.9 to 9.8 GPM (35° F rise)

98° - 140° F

120° F (factory default)

Natural or Propane (ensure unit matches gas type)

Outdoor only

Natural Gas: 85%

Propane: 83%

Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT

Water flow sensor, electronic water control and by-pass control

15 - 150 PSI (50 PSI or above is recommended for maximum flow)

© 2008 Rinnai Corporation

3237W-ASME SP-1 4/2008

FLOW TABLE

Water Flow Capacity Curve

R

This model has been built in accordance with the requirements of
the ASME Boiler and Pressure Vessel Code and has received the
Certificate of Authorization from the National Board. The heat
exchanger has the NB and the HLW stamps.