Oregon Scientific THC268 User Manual

Multi-channel cable free remote thermo sensor

Advertising
background image

MULTI-CHANNEL

CABLE FREE

REMOTE THERMO SENSOR

MODEL: THC268

ENGLISH

USE’S MANUAL

INTRODUCTION

Congratulations on your purchasing the THC-268 Remote Thermo Sensor.
The Remote Thermo Sensor is used with the Oregon Scientific 433MHz
Multi-Channel In-Out Thermometers , Wireless Weather Stations, Weather
Clocks etc. to monitor temperature changes of remote or outdoor sites.
Operation is easy and no wire installation is required.

MAIN FEATURES:

A LCD

Displays the current temperature monitored by the remote unit and
indicates the selected channel

B LED INDICATOR

Flashes when the remote unit transmits a reading

C TEMPERATURE SENSOR PROBE

On 10 feet ( 3 meters ) cable.

D °C/°F SLIDE SWITCH

Selects between Centigrade ( °C ) and Fahrenheit ( °F )

E CHANNEL SLIDE SWITCH

Designates the remote unit Channel 1, Channel 2 or Channel 3

F RESET BUTTON

Returns all settings to default values

G BATTERY COMPARTMENT

Accommodates two AA-size batteries

H BATTERY DOOR

I

WALL-MOUNT HOLDER

Supports the remote unit in wall-mounting

J REMOVABLE TABLE STAND

For standing the remote unit on a flat surface

COMPATIBLE PRODUCTS

Following is the list of some Oregon Scientific products that the THC268
is compatible with:

Cable Free Weather Forecaster with Thermo-Hygrometer and Radio
Controlled Clock: BAR122HGA

Cable Free Weather Forecaster with Thermo-Hygrometer, Radio Con-
trolled Clock and Ice Alarm: BAR913HGA

Cable Free Weather Station with Thermo-Hygrometer and Radio Con-
trolled Clock: BAR938HGA

Cable Free Thermo-Hygrometer: EMR963HG

Cable Free Thermometer with Radio Controlled Clock: RMR112

Cable Free Weather station: WMR968

Cable Free Weather station: WMR112

BEFORE YOU BEGIN

For best operation,

1. Assign different channels to different remote units.

2. Insert batteries for remote units before doing so for the main unit.

( Main unit of models listed under optional items )

3. Place the main unit as close as possible next to the remote unit, reset

the main unit after installing batteries. This will ensure easier
synchronization between the transmission and reception of signals.

4. Position the remote unit and main unit within effective transmission

range, which, in usual circumstances, is 20 to 30 meters(upto 100 feet).
Note that the effective range is vastly affected by the
building materials and where the main and remote units are
positioned. Try various setups for best result.
Though the sensor is weather proof and meant to be used outdoors,
it should be placed away from direct sunlight, rain or snow.

BATTERY AND CHANNEL INSTALLATION

The remote unit uses two AA-size batteries. To install them,

1. Remove the screws on the battery compartment.

2. Select the channel number on the CHANNEL slide switch.

3. Select the temperature display unit on the °C/°F slide switch.

4. Insert the batteries strictly according to the polarities shown inside.

5. Replace the battery compartment door and secure its screws.

CHANGE CHANNEL

Once a channel is assigned to a unit, you can only change it by removing
the batteries and repeating the above procedure.

LOW-BATTERY WARNING

Replace the batteries of the sensor when the low-battery indicator of the
channel represented by the sensor shows up on the main unit.

OPERATION

Once batteries are in place, the sensor will start transmitting samplings
at 40-second intervals.
The current temperature will be shown on the LCD in the selected unit
( °C/°F ) at the designated channel. The unit ( °C/°F ) shown on the main
unit is determined by the setting on the main unit.

HOW TO INSTALL THE TEMPERATURE
SENSING CABLEG

Secure the sensor to an area you want to monitor. Do not expose it to
direct sunlight.

THE RESET BUTTON

See the user’s manual of your main unit for further information.
This button is only used when the unit is operation in an unfavorable
way or malfunctioning. Use a blunt stylus to hold down the button. All
settings will return to their default values.

HOW TO USE THE TABLE STAND OR WALL
MOUNTING

This sensor comes with a wall-mount holder and a removable stand.
Use either to set up the unit.

PRECAUTIONS

This product is engineered to give you years of satisfactory service if
you handle it carefully. Here are a few precautions:

1. Do not immerse the unit in water.

2. Do not clean the unit with abrasive or corrosive materials. They may

scratch the plastic parts and corrode the electronic circuit.

3. Do not subject the unit to excessive force, shock, dust, temperature

or humidity, which may result in malfunction, shorter electronic life
span, damaged battery and distorted parts.

4. Do not tamper with the unit’s internal components. Doing so will

invalidate the warranty on the unit and may cause unnecessary dam-
age. The unit contains no user-serviceable parts.

5. Only use fresh batteries as specified in the user’s manual. Do not mix

new and old batteries as the old ones may leak.

6. Always read the user’s manual thoroughly before operating the unit.

SPECIFICATIONS

Temperature Measurement

Displayed range

: -50.0°C to + 70.0°C

( -58.0°F to 158.0°F )

Proposed operating range

: -20.0°C to + 60.0°C

( 4.0°F to 140.0°F )

Temperature resolution

: 0.1°C ( 0.2°F )

RF Transmission Frequency

: 433 MHz

No. of Remote unit

: Maximum of 3

RF Transmission Range

: Maximum 30 meters (100 feet)

Temperature sensing cycle

: around 40 seconds

Power

: use 2 pcs UM-3 or “AA”

1.5V alkaline battery

Weight

: 80.5 g (2.84ounces)

Dimension

: 105 x 70 x 21mm

(4.13 x 2.76 x.83 inches)

NOTE ON COMPLIANCE

This device complies with Part 15 of the FCC Rules. Operation is sub-
ject to the following two conditions: (1) This device may not cause
harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operations.

Warning: Changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority
to operate the equipment.

FCC :

NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications.

However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the inter-
ference by one or more of the following measures:

orient or relocate the receiving antenna.
-

Increase the separation between the equipment and receiver.

-

Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.

-

Consult the dealer of an experienced radio/TV technician for help.

Company Name: Oregon Scientific, Inc.
Address: 19861 SW 95th Place, Tualatin, Oregon 97062, USA
Telephone Number: 1-800-853-8883

CUSTOMER ASSISTANCE

Should you require assistance regarding this product and its operation,
please contact our customer care department at 800-853-8883 or via
email at [email protected].

I

J

1

1

1

CAUTION

- The content of this manual is subject to change without

further notice.

- Due to printing limitation, the displays shown in this

manual may differ from the actual display.

- The contents of this manual may not be reproduced

without the permission of the manufacturer.

WARRANTY

This product is warranted to be free of defects in manufacturing

for 90 days after purchase. For technical support please call

800-853-8883 ( Monday-Friday; 8am-5pm PST ).

Defective product returns should be directed to the place of retail

purchase. If this is not possible, all direct returns must include a
Return Authorization Number from Oregon Scientific, together

with proof of purchase date, your name and address, shipped

prepaid to Oregon Scientific Inc, 19861 SW 95th place Tualatin,

OREGON 97062, USA.

This warranty does not cover a product subjected to abuse,

misuse of accidental damage.

thc268 usa p65

11/07/2001 11:25 AM

1

Advertising