Omron NE-U22V User Manual

Cleaning instructions – each use, Model ne-u22v microair vibrating mesh nebulizer

Advertising
background image

CLEANING INSTRUCTIONS – EACH USE

Model NE-U22V

MicroAir Vibrating Mesh Nebulizer

WARNING

FAILURE TO PROPERLY CLEAN AND DISINFECT THE MICROAIR

COMPONENTS WILL RESULT IN THE RISK OF BACTERIAL GROWTH,

ILLNESS, AND SERIOUS INJURY FROM CONTAMINATION,

COMPROMISED MEDICATION DELIVERY, AND POSSIBLE DAMAGE

TO THE DEVICE.

CAUTION

®

CAUTION

Do

NOT operate the device if not properly assembled.

Do

NOT operate the device if not working correctly.

Do

NOT rinse or immerse the Main Unit in any liquid.

Do

NOT wash or rinse any of the parts under the strong running water.

Do

NOT touch the mesh with your hand or any other object.

Following the cleaning instructions after each use will prevent any remaining

medication in the bottle from drying, adhering to the mesh cap, and resulting in

the device not nebulizing effectively.

Wash the Medication Bottle, Mesh Cap, Mask, Mouthpiece, and Mask

Adapter after each use.

It is important to clean your unit using distilled water after each use.

Remove the Mouthpiece or Mask and the Mask Adapter from the Main Unit.

1.

Remove the Medication Bottle from the Main Unit.

2.

Open the Medication Bottle and discard any remaining medication.

3.

Attach the Medication Bottle to the Main Unit. Open the Mesh Cap.

4.

Pour a small amount of distilled water into the Medication Bottle and close

5.

the Mesh Cap.

Turn on the device to nebulize the distilled water for 1 to 2 minutes to remove

6.

residual medication from the mesh holes.

Turn off the device and remove the Medication Bottle from the Main Unit.

7.

Remove the Mesh Cap from the Medication Bottle and discard any remaining

8.

distilled water from the Medication Bottle.

Rinse the Medication Bottle, Mesh Cap, Mask, Mouthpiece, and Mask Adapter with

9.

distilled water.

Gently wipe off excess water with a soft clean cloth or allow the parts to air dry in

10.

a clean environment.

Assemble the device. Store the device in the Storage Case or in a clean environment.

11.

OVER

310974_NE-22UV Cleaning Inst_R3.indd 1

7/22/11 2:51:23 PM

Advertising