Accessories & troubleshooting, Call customer service hot line, Troubleshooting guide – Oreck XL Рrofessional air purifier AIR8 Series User Manual

Page 7

Advertising
background image

7

Whenever calling, please be sure to have your model from the
data plate.

CALL CUSTOMER SERVICE HOT LINE

USA:1-800-989-3535 Canada: 1-888-676-7325

Accessories (Sold Separately)

ITEM

PART #

1.

Pre-Filter

7780-8041

2.

Ionizer/Electronic Collector Cell

09-5510-7065

3.

Charcoal Odor Absorber (Set of 4)

AT4PK7

4.

Wall Mounting Kit

8660-0201

5.

Oreck Fresh Air

®

Scent Cartridges

Spring Mulberries

®

, 8pk.

FA2PK

Blooming Jasmine

®

, 8pk.

FA3PK

USA: 1-800-989-3535

Canada: 1-888-676-7325

Outside the USA and Canada,

contact your local Oreck Distributor.

U

NIT DOES NOT TURN

ON

I

NDICATOR LIGHT ON

UNIT IS FLASHING RED
OR HAS TURNED RED

R

ED INDICATOR LIGHT

WILL NOT TURN OFF

U

NIT DOES NOT

REMOVE POLLUTANTS

U

NIT SPARKS

,

CRACKLES AND POPS

D

OES NOT REMOVE

ODOR

U

NIT STILL DOES NOT

OPERATE PROPERLY

1. Power Cord

2. Selector Switch

3. Front Grill

Ionizer/Electronic
Collector Cell

Ionizer/Electronic
Collector Cell

Ionizer/Electronic
Collector Cell

Ionizer/Electronic
Collector Cell

Old Charcoal Odor
Absorber

Check all the above
points

1. Plug in power cord

2. Set selector switch

for desired blower
speed.

3. Reinsert front grill

until it is flush with
cabinet front. Tap
grill lightly, if
necessary, to fully
insert.

Wash Collector Cell.
Make sure it is
thoroughly clean & dry
before re-installing it.

1. Collector Cell may

not be completely
dry.

2. Cell may be

damaged with a
broken wire.

3. The “Dirty Cell”

sensor may not be
working correctly.

4. If you believe the

Collector Cell is
damaged or the unit
is not working
correctly, return the
unit to the Service
Center.

Wash Collector Cell.
Make sure it is
thoroughly clean & dry
before re-installing it.

1. Sparking or

popping noise
occurs when a
large particle is
captured in the
Collector Cell.

2. If the unit is arcing

excessively, the
Cell may be dirty.
Try cleaning the
Collector Cell.

3. If excessive

arcing continues
after proper cleaning,
the Collector Cell
may be damaged
or wet. Return unit
to the Service
Center.

Replace Charcoal
Odor Absorber.

Return unit to the
Service Center.

ALL OTHER SERVICING SHOULD BE DONE BY AN
ORECK AUTHORIZED SERVICE CENTER.

P

ROBLEM

C

HECK

W

HAT

T

O

D

O

ACCESSORIES &
TROUBLESHOOTING

Troubleshooting Guide

Service problems that appear to be major can often be solved
easily. You can be your own troubleshooter by reviewing the
chart below. It pinpoints problems and how to correct them.
Remember, check the simple things first.