Gas Supply:

Natural Gas – 6 inch water column. (14.9mb) min., 8 inch (20mb) nominal
Propane Gas – 11 inch water column. (27.4 mb), 14 inch (37mb) maximum

Electrical Power Supply:

PRG304, PRG36 and PRG48 Models – 120 VAC, 60 Hz., 1Ph., 20 Amp circuit.
PRDS304 Model - 120/240 VAC, 50/60 HZ., 1Ph., 20 Amp circuit.
PRDS36 Models – 120/240 VAC, 50/60 Hz., 1Ph., 35 Amp circuit.
PRDS48 Models – 120/240 VAC, 50/60 Hz., 1Ph., 50 Amp circuit.

IMPORTANT: Save these instructions for the Local Electrical Inspector’s use.

INSTALLER: Please leave these Installation Instructions with this unit for the owner.

OWNER: Please retain these instructions for future reference.

C A N A D I A N G A S A S S O C I A T I O N

A P P R O V E D

®

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

IMPORTANT:

LOCAL CODES VARY. INSTALLATION, ELECTRICAL CONNECTIONS,

GAS CONNECTIONS, AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES.

INSTALLATION INSTRUCTIONS MANUAL

PROFESSIONAL RANGES

ALL-GAS MODELS – PRG304, PRG36 AND PRG48