Tobacco Smoke Detector ZSSD9

Operating and Installation Instructions

No Smoking Detector containing
• Selective Precision Sensor-Chamber
• Unique VWS Technology (voice warning system) patent applied.

The ZSSD9 Tobacco Smoke Detector anti smoking smoke alarm
detects cigarette, cigar and pipe tobacco smoke at an early stage
and warns by means of a loud, voice warning announcement by
way of example ‘This is a no smoking area, please extinguish all
smoking materials immediately’. The ZSSD9 Tobacco Smoke Detector
smoke detector operates according to the ionisation principle. If the
concentration of smoke particles in the enclosure reaches a pre-
determined level it will activate the voice waning announcement.
This device contains radioactive substances and should be disposed
of under instructions from the manufacturer!

Product characteristics:-
Smoke sensing
Every device is separately calibrated in order to avoid false alarms.
Tobacco Smoke Detector is designed to detect small amounts of
cigarette, cigar or pipe smoke. The device is electronically regulated
internally, thereby maintaining a constant sensitivity of the alarm.
When Tobacco Smoke Detector detects small amounts of cigarette,
cigar or pipe tobacco smoke it will play its announcement message
then shut down for 4 minutes after which time it will be ready to
activate again.

Signal lamp (LED)
A flashing small light (every 43s) signals that the device is
functioning correctly.

Fully automatic test function
Advanced electronics ensure the best possible operating readiness
by means of an automatic self-test function.

Battery warning function.
When the battery begins to run low the device will emit a short
beep warning sound followed a voice message saying ‘My battery
is running low replace it with a new battery immediately’. This
is repeated every 43 seconds for up to 400 times after which the
waning beep will continue to function for up to I month.

Test Button
Momentarily pressing the Test Button will initiate a test sequence.
The voice warning announcement will be played. This ensures the
smoke detector is working correctly. If at this time the ‘Low Battery’
voice warning is played the battery is beginning to run low and
should be changed as soon as possible.

Voice Warning.
The voice warning system is a unique patented system which
is digitally generated and recorded on a proprietary device
manufactured for sole use of the ZSSD9 range of devices.

Approved quality
Thoroughly tested to guarantee highest reliability and a long service
life. Produced under rigid quality controls. Certified according to the
European norm EN ISO 12239 for single smoke detectors. CE and TÜV
certified security.

Placement Location
• Should be mounted on the ceiling in areas selected for No Smoking.
• One device for every 65 cubic metres approximately. The minimum
requirement for large areas request advice from your product
supplier.
• For complicated or extensive properties please request qualified
advice from your product supplier.
Information on fire protection is available at your local Fire Station
helpdesk.

The following locations shall be avoided:
• Next to doors, windows, ventilators etc. where draughts can
deviate smoke from the sensor.
• In small or poorly ventilated garages or kitchens where waste gas
or vapours may cause false alarms.
• In areas where dust and dirt can interfere with the operation or
cause false alarms.
• In areas where insects or vermin may effect the integrity of the
alarm.
• In damp or humid areas (e.g. in the bathrooms).
• In areas where the temperature may often fall below –5°C or
exceed +38°C.