Program example for parameter writing – Toshiba TOSVERT VF-S15 series option unit Function E6581830 User Manual

Page 43

Advertising
background image

E658130

- 42 -

6.6.

Program example for parameter writing

Example 6 shows

a ladder logic to

chang the setting of f311 of station 1 inverter to 1

f311

: Reverse-run prohibition reading code number: 2311H (hexadecimal)

Reverse-run prohibition set data: 1 (decimal)































Refer to 5.5.8 for detail.

X0

X0F X1

SW80.0

M0

X20

M300

M301

X100F

[ MOV H2311 W102]

M302

X100F

[ MOV W2 D2]

( M0)

[ PLS M300]

[ SET M301]

[ MOV K1 W103]

[ SET Y100F]

[ RST M301]

[ SET M302]

[ RST Y100F]

[ RST M302]

[ END]

Check the ready of the Station 1

Write f311 write code (2311H) to
RWw2 and r

everse-run prohibition

setting

Turn on the instruction code
execution

Read reply code (RWr2) to D2 when the
Instruction code execution completion
flag

Turn off the instruction code
execution

Example

Advertising