INSTRUCTIONS FOR USE

To Check the Status of a Phone Circuit

1) Move slide switch on left side of Turbo Tone

to the

STATUS position.

2) Connect black lead to TIP and the red lead to RING or one

lead to each wire of the pair if designation is unknown.

• If NRM lights up, it means the polarity is correct and the

black lead is connected to TIP.

• If the REV lights, then the leads are reversed.

• If the NRM or REV LED is bright, the line is not in use.

• If the LED is dim, the circuit is in use.

• If both NRM and REV are on or flashing, an AC voltage

is present.

Application Hints: The TIP signal is nominally at ground potential.
Attaching the black lead to a ground point and connecting the
red lead to each wire of the pair can identify the RING line. When
the red lead is connected to RING, the NRM LED will light.

The status LEDs also indicate a ringing line by both NRM and
REV LEDs flashing brightly. To verify a phone line, connect the
Turbo Tone

in STATUS mode to the line to be tested and call

that line’s number from another line. The Turbo Tone

status

LEDs should indicate a ringing line.

To Check Continuity of a Circuit

Use only on non-energized circuits. Any energy present may
damage the Turbo Tone

or cause erroneous results. Turn off

tone if necessary.

1) Move slide switch on left side of Turbo Tone

to the

CONT position.

2) Connect one lead of Turbo Tone

to each end of the circuit

to be tested. If the DC resistance of the path is approximately
11,000 ohms or less, the REV LED will light.

--2--

Note: The RJ jumper cable that has been provided with the

Turbo Tone

uses a unique colored modular connector

that can be plugged into a RJ11 jack or a RJ45 jack
without damaging either. Thereby allowing CAT 5 output
points to be accessed without using an adapter.

Warning!

Do not attach to live AC circuits. This could cause an extreme
shock hazard and damage the Turbo Tone

. Attachment to an

unknown circuit should always be in STATUS mode.

--1--

FEATURES

• Four tone amplitude levels—

normal and half plus TURBO normal and half

• Half amplitude is unbalanced for stronger

signal on twisted pairs

• Three distinctly different tones selected

from front panel

Constant Amplitude Signal over life of battery

for 100% signal strength all the time

Auto-off—tone turns off after 3 hours—

no dead battery if left on

• Tone may be added in any mode—

allows phone sets without monitor feature
to pick up tone

• No power draw in continuity mode with leads open—

no dead battery if left in continuity

• RJ jack allows use of modular cable without adapters

TG200

Part No.

TONE GENERATOR

Operating Instructions

Turbo Tone

TG200 Page 1