Page 52

4.9.3. SIO(RS232) Special Commands

0xF2F10018

Auto-Sync Mode control register
Bit 31 : auto sync enable
Bit 30 : SIO enable mode (0 : Custom mode, 1 : IIDC v1.31)
Bit 27 : auto sync complete (read only. 1: ready, 0: not yet auto-sync)

Read/Write

Custom commands are valid when the Bit30 is to be set “0”(zero).

SIO(RS232) custom commands are non IIDC compliant which is a specific mode for the cameras.

Before using these commands serial communication parameters must be set at Serial_Mode_Reg(F2F22000h)

F2F10018 means that the RS232 command is valid.

Baud Rate

Stop Bit

Parity

Flow Control

57600 bps (default)

1 bit

None

Non

Command format : [STX] [Command] [Data] [ETX]

[STX]

: Command start character : ‘S’

Command] : Command length is 2byte. See next page command table.

[Data]

: Data length is varied with each command. Data format is hexadecimal: ‘0’~’9’, ‘A’~’F’.

[ETX]

: Command end character : ‘Z’

Return value

G’

: Command complete acknowledge.

Gdd..d” : “dd..d” is return data and hexadecimal character.

U’

: Undefined command.

Valid Character: ‘0’~’9’, ‘A’~’F’, ‘S’,’Z’ Invalid character is received is discarded.

Example: Gain setting command with 0x200 value.

All of “SA0200Z”, “S A0 200 Z”, “SA0 200Z”, “S A0200 Z”, and “SKA0V200Z” are parsed to

SA0200Z Z”, and “SKA0V200Z” are parsed to “SA0200Z”.

SIO(RS232) Commands

STX Command

Data

Length

ETX

Return

Value

Function

S

A0

3Bytes

Z

G

Gain control (0x000 ~ 0x30F(BW Model) or 2D3(Color Model))

(see gain mapping graph)

Ex) SA0200Z : Gain index value 512 (18dB)

S

A1

3Bytes

Z

G

Shutter speed control
(0x001 ~ 0xCFB) (see shutter speed table)

S

A2

1Bytes

Z

G

Set/Clear auto shutter speed and auto gain
Bit 0 : Auto gain Bit 1 : Auto shutter speed
Ex) SA21Z : set auto gain and clear auto shutter speed

SA23Z : set auto gain and auto shutter speed

SA20Z : clear auto gain and auto shutter speed

S

A3

2Bytes

Z

G

Auto exposure control (0x00~0x64)

S

A4

1Bytes

Z

G

Gamma control (0x0~0x19) (see gamma table)

S

A5

3Bytes

Z

G

Brightness control (0x000~0x800)

S

A6

3Bytes

Z

G

Sharpness control (0x000~0x3F8)

S

A7

1Bytes

Z

G

ISO control 1: ISO enable, 0 : disable

S

A8

1Bytes

Z

G

Trigger control 1: trigger enable, 0 : trigger disable