Vivotek FD6121V User Manual

Page 78

Advertising
background image



- 74 -

www.vivotek.com

T: 886-2-82455282
F: 886-2-82455532


winname_<1~3>
(r/w)

<text string shorter
than 14 characters >

name of motion window #1
<blank>

winleft_<1~3>
(r/w)

0 ~ 352 for CCD
0 ~ 320 for CMOS

Left coordinate of window position.
<0>

wintop_<1~3>
(r/w)

0 ~ 288 for PAL
0 ~ 240 for
NTSC & CMOS

Top coordinate of window position.
<0>

winwidth_<1~3>
(r/w)

0 ~ 352 for CCD
0 ~ 320 for CMOS

Width of motion detection window.
<0>

winheight_<1~3>
(r/w)

0 ~ 288 for PAL
0 ~ 240 for
NTSC & CMOS

Height of motion detection window.
<0>

winobjsize_<1~3>
(r/w)

0 ~ 100

Percent of motion detection window
<0>

winsensitivity_<1~
3>
(r/w)

0

~

100

Sensitivity of motion detection
window
<0>

update
(w)

1

Update the above motion detection
settings to take effect


Group: DDNS

NAME VALUE

DESCRIPTION

enable
(r/w)

0, 1

Enable or disable the dynamic dns.
<0>

provider
(r/w)

1 ~ 4

dyndns.org (dynamic)
dyndns.org (custom)
tzo.com
dhs.org
<1>

hostname
(r/w)

Text string shorter than
127 characters.

Your dynamic hostname.
<blank>

usernameemail Text string shorter than Your user or email to login ddns service