Scompu defrost test – Viking DMOC205SS User Manual

Page 22

Advertising
background image

20

DMOC205SS
VMOC205SS

S

COMPU DEFROST TEST

(1) Place one cup of water in the center of the turntable tray in the oven cavity.
(2) Close the door, touch the "DEFROST" pad twice and touch the Number pad "5". And then touch the

"START" pad.

(3) After 2 sec. Now the oven is in DEFROST cooking condition.
(4) The oven will operate as follows.

WEIGHT

1ST STAGE

2ND STAGE

3RD STAGE

4TH STAGE

LEVEL

TIME

LEVEL

TIME

LEVEL

TIME

LEVEL

TIME

0.5lbs

70%

47sec.

0%

52sec.

50%

32sec.

30%

40sec.

(5) If improper operation is indicated, the control unit is probably defective and should be checked.

R

RELAY TEST

Remove the outer case and check voltage between Pin Nos. 7 and 9 of the 9- pin connector (A) on the
control unit an A.C. voltmeter. The meter should indicate 120 volts, if not check the oven circuitry.

Shut-off, Cook and Heater Relay Test

These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation or convection
cooking operation.

DC. voltage indicated ............. Defective relay.
DC. voltage not indicated ........ Check diode which is connected to the relay coil. If diode is good, control

unit is defective.

RELAY SYMBOL

OPERATIONAL VOLTAGE

CONNECTED COMPONENTS

RY1

Approx. 19.0V D.C.

Oven lamp / Turntable motor

RY2(COOK)

Approx. 18.0V D.C.

Power transformer

RY3(HEATER)

Approx. 18.0V D.C.

Heating element

RY4

Approx. 19.0V D.C.

Damper motor

RY5

Approx. 19.0V D.C.

Convection motor

RY6

Approx. 19.0V D.C.

Cooling fan motor

TEST PROCEDURES

PROCEDURE

LETTER

COMPONENT TEST

If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable is
making good contact, verify that the door sensing switch (stop switch) operates properly; that is the
contacts are closed when the door is closed and open when the door is open. If the door sensing switch
(stop switch) is good, disconnect the flat ribbon cable that connects the key unit to the control unit and
make sure the door sensing switch is closed (either close the door or short the door sensing switch
connecter). Use the key unit matrix indicated on the control panel schematic and place a jumper wire
between the pins that correspond to the STOP/CLEAR pad making momentary contact.
If the control unit responds by clearing with a beep the key unit is faulty and must be replaced. If the
control unit does not respond, it is a faulty and must be replaced. If a specific pad does not respond,
the above method may be used (after clearing the control unit) to determine if the control unit or key
pad is at fault.

Q

KEY UNIT TEST

G 1

G 2

G 3

G 4

G 5

G 6

G 7

G 8

G 9

G10

G11

G12

STOP

CLEAR

REHEAT

LOW MIX

BAKE

SLOW
COOK

HELP

TIMER

POWER

LEVEL

CLOCK

ADD-A-

MINUTE

DEFROST

CONVEC

BROIL

CONVEC

ROAST

CONVEC

BAKE

BROIL

SENSOR

COOK

POPCORN

KEY UNIT

350°F

375°F

400°F

425°F

450°F

6

7

8

9

0

100°F

150°F

275°F

300°F

325°F

1

2

3

4

5

CONVEC

PREHEAT

START

TOUCH ON

HIGH MIX

ROAST

Advertising
This manual is related to the following products: