REMOVAL
1. Disconnect oven from power supply and remove the

outer case.
Remove turntable tray and turntable support from oven
cavity.

2. Remove three (3) screws holding lower oven hinge.
3. Remove the lower oven hinge from oven cavity bottom

flange.

4. Remove door assembly from upper oven hinge on the

oven.

5. Door assembly is now free.

Note:

When the individual parts are replaced, refer to
"Door Disassembly".

6. On re-installing door, insert the upper oven hinge into

the door hinge pin. Then while holding door in place.

6. Now, the control unit and frame assembly are separated.
NOTE; 1. Before attaching a new key unit, remove

remaining adhesive on the control panel frame
surfaces completely with alcohol and so on.

2. When a attaching the key unit to the control

panel frame, adjust the lower edge and right
edge of the key unit to the correct position of the
control panel frame.

3. Stick the key unit firmly to the control panel

frame by rubbing with soft cloth not to scratch.

THIRD DOOR SWITCH, DOOR SENSING SWITCH, PRIMARY

INTERLOCK SWITCH AND MONITOR SWITCH

ADJUSTMENT

If the door sensing switch, third door switch, primary
interlock switch and monitor switch do not operate properly
due to a misadjustment, the following adjustment should be
made.
1. Loosen the two (2) screws holding latch hook to the oven

cavity front flange.

2. With door closed, adjust latch hook by moving it back

and forth, and up and down. In and out play of the door
allowed by the latch hook should be less than 0.5mm.
The vertical position of the latch hook should be adjusted
so that the door sensing switch and primary interlock
switch are activated with the door closed. The horizontal
position of the latch hook should be adjusted so that the
plungers of the monitor switch and the third door switch
are pressed with the door closed.

3. Secure the screws with washers firmly.
4. Check the all switches operation. If each switch has not

activated with the door closed, loosen the screw and
adjust it.

After adjustment, check the following.
1. In and out play of door remains less than 0.5mm at the

THIRD DOOR SWITCH, DOOR SENSING SWITCH, PRIMARY INTERLOCK SWITCH AND MONITOR SWITCH

REMOVAL

1. Disconnect oven from power supply and remove outer

case.

2. Discharge high voltage capacitor.
3. Remove the control panel assembly, refer to "Control

Panel Removal".

4. Disconnect wire leads from each of the switches and

fuse holder.

5. Remove two (2) screws holding latch hook to oven

flange.

6. Remove latch hook assembly from oven flange.
7. Push outward on the one (1) stopper tabs holding each

of switches place.

8. Switch is now free.

At this time switch lever will be free, do not lose it.

Re-install
1. Re-install switch lever and each interlock switch in its

place. The primary interlock switch is in the lower
position and the door sensing switch and thir door switch
are in the upper position and the monitor switch is in the
middle position.

2. Re-connect wire leads to each switches and fuse holder.

Refer to pictorial diagram.

3. Secure latch hook (with two (2) mounting screws) to

oven flange.

4. Make sure that the monitor switch is operating properly

and check continuity of the monitor circuit. Refer to chapter "Test Procedure" and Adjustment procedure.

latched position.

2. The door sensing switch and primary interlock switch

interrupt the circuit before the door can be opened.

3. Monitor switch contacts close when door is opened.
4. The third door switch contacts open when the door is

opened.

5. Re-install outer case and check for microwave leakage

around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)

Figure C-4. Latch Switch Adjustments

LATCH HOOK

LATCH
HEADS

DOOR SENSING
SWITCH

MONITOR SWITCH

PRIMARY
INTERLOCK SWITCH

SWITCH LEVER

OPEN LEVER