Warning – Wayne-Dalton TORQUEMASTER 3663-372 User Manual

Page 41

Advertising
background image

Up-Down Button:

Momentarily pressing the Up/Down button activates the door. If an
out-of-balance condition causes the door to stop while opening or
reverses the door while closing, apply constant pressure to the
Up/Down button until the door is fully open or closed. This will allow
the opener to move the door in an out of balance condition, until the
problem is corrected (see Troubleshooting). The Up/Down button
(when unit is closed) can be activated by pressing flip cover.

THE SEVERE OUT-OF-BALANCE CONDITION MUST BE CORRECTED
IMMEDIATELY. FAILURE TO MAKE ADJUSTMENTS/REPAIRS, COULD
RESULT IN SEVERE OR FATAL INJURY.

Light Button:

Momentarily pressing the Light Button turns on the light fixture. The
light fixture will remain on until either the Light Button is pressed again
or the door is activated. The light fixture automatically turns on with a
door activation and remains on for five minutes. Pressing the light
fixture button before the five minutes has elapsed will turn off the light
fixture. While the door is in motion, the Light Button functions identically
as the Up/Down button, stopping or reversing the door immediately.

Timer Button:

Momentarily pressing the Timer Button causes a delayed activation of a
stationary fully open door. The opener will signal seven beeps (approx.
8 seconds) then beep constantly for two seconds prior to closing the
door, allowing time to exit the garage when the opener is in the timer
mode. Pressing any button, except for the profile button while the
opener is beeping cancels the timer mode.

NOTE: The Timer feature will only function with the door in the
full open position. Pressing the Timer Button with a stationary
door in any other position will cause the opener to beep four
times and the door will not be activated
.

While the door is in motion, the Timer Button functions identically as
the Up/Down button, stopping or reversing the door immediately.

Slide Switch:

The Slide Switch has two positions: Normal, and Door lock.

Normal position:

Move the Slide Switch to normal position for all normal functions of the
opener. The normal position will cancel the door lock feature.

NOTE: When the Slide Switch is moved to the unlocked
position the opener will beep once.

Door Lock position:

If the door is stopped (fully open, fully closed or partially open) move
the Slide Switch to the door lock position to suspend all normal
functions of the opener. The opener will remain completely disabled
and non-operational in this mode. All wall stations, transmitters and
keyless entry units are ignored until the Slide Switch is moved to the
normal position. If the door is moving when the Slide Switch is moved
to the door lock position, the door lock mode is not activated and all
functions of the opener remain active.

NOTE: When the Slide Switch is moved to the locked position
the opener will beep twice.

Operating the Wireless Wall Station

Backlit LED Light:

The red LED blinks intermittently to help you locate the wall station
in a dark garage. This blink rate can be changed for longer battery
life or can be turned off. The default blink rate is one blink every 3
seconds. For longer battery life the blink rate can be changed to
blink once every 6 seconds. To change the blink rate, remove the
battery cover and remove one battery. Re-install the battery and
within 2 seconds, press the Light button. Re-install the battery cover.

For longest battery life, the blink can be turned off. To turn off the
blink, remove the battery cover and remove one battery.

Re-install the battery and within 2 seconds, press the pet button.
Re-install the battery cover.

NOTE: The wall stations red LED will light while any wall
station button remains pressed.

Pet Position:

Pressing the Pet button opens a closed door to a preset position
between eight and thirty inches above the floor, allowing pets to
enter and exit the garage without the door being fully open. The
door must be fully closed to activate the pet open feature. Pressing
the Pet button with a stationary door in the pet open position will
cause the door to close. Pressing the Up/Down button while the
door is in the pet position will cause the door to open. While the
door is in motion, the pet button functions identically to the Up/Down
button, stopping or reversing the door immediately. The pet feature
allows for custom setting of the pet position door height. See
Customizing the Settings on page 37.

NOTE: A door in the “pet position” (open 8-30 inches) is not locked
and should not be used as a secured door position.

Profile Routine:

Press and hold the Profile button for 5 seconds to initiate the
“Profile Routine”. See Customizing the Settings on page 37.

NOTE: The wall stations red LED will light while any wall station
button remains pressed. See Maintenance section for battery
replacement.

Pet Button

Light Button

Up/Down Button

Timer Button

Profile Button

Slide Switch

WARNING

34

Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.

You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

OPERA

TION

Advertising