Windsor SPIRIT DUAL SPD-J User Manual

Page 5

Advertising
background image

Preparing the SPIRIT DUAL:

For Hard Floor:

1.)

Install the optional kit : Vac Shoe Squeegee (p/n

02285). Raise the SPD vac shoe and place the squeegee
assembly over the vac shoe intake. Center the squeegee
on the vac shoe and secure by tightening the two retain-
ing knobs.

CAUTION: Make sure that the machine is un-

plugged, switches are turned off and both solution

tanks are empty before beginning brush removal or

replacement.

2.)

Now install the hard floor brush. Tilt the machine

back far enough to grasp the brush. If the carpet brush
is already installed, proceed with step 3 to remove it.
If no brush is installed, proceed with step 4.

3.)

To remove brush, pull the brush release knob

back until the brush can be swung out from the housing

and pull the brush off of the drive end.

4.)

To replace, align the pulley drive pins on the knob

driver in the housing with the slots in the brush and
slide over the knob driver.

5.)

Pull the brush release knob back, align

flat

sides of the brush stub axle in the housing and swing
the brush into place. Then release the knob, returning
to the locked position.

Refer to page 17 for parts

outlined in these steps.

6.)

Set the water control switch on the front of the

machine to “LOW”.

NOTE: If water does not spray

after 5 seconds when the switch is in the “LOW”

position it may be necessary to place it in the

“HIGH” position to start the flow, then return it to

the “LOW” position for hard floor use.

For Carpet:

1.)

Remove squeegee from vac shoe by loosening

the two retaining knobs.

2.)

Install carpet brush as described above.

3.)

Set the water control switch on the front of the

machine to “HIGH”.

Filling Solution Tank:

1.)

Set dome and recovery tank to the side.

2.)

Use a clean bucket to fill the solution tank

with hot water.

3.)

If necessary add a cleaning concentrate for

use in hot water extractors. Closely follow manu-

facturer’s instructions found on container. Read
ingredients listed on the container to ensure

CAUTION: Use only the suitable chemicals

listed below. Using incompatible chemicals will

damage the machine. Damages of this type are

not covered under warranty. Carefully read

ingredients on manufacturer’s label before us-

ing any product in this machine.

SUITABLE INCOMPATIBLE
CHEMICALSCHEMICALS

Alkalis
Clorox II Bleach*
Defoaming Agents
Detergents
Hydroxides
Oxygen Bleaches
Soaps
Sta-Puf Fabric Softener*
Vinegar
White Monday Bleach*

Aldehydes
Aromatic Hydrocarbons

Butyls
Carbon Tetrachloride

Chlorinated Bleaches
Chlorinated Hydrocarbons
D-Limonene

Methyls (MEK)

Perchlorethylene(perc)
Phenols

l

Registered Trademark

Trichlorethylene

4.)

Place the recovery tank onto the solution tank.

5.)

Set the dome in place on the recovery tank.

Dome must be seated correctly to ensure

proper vacuum seal.

5

Advertising
This manual is related to the following products: