Warning – Windsor SPIRIT DUAL SPD-J User Manual

Page 8

Advertising
background image

This product contains moving parts.

To reduce the risk of injury; unplug the

machine before servicing.

Maintenance and repairs must be done
by qualified personnel ONLY.

CAUTION:

Using non-Windsor parts to repair this
machine will void the 6-3-1 warranty.

Warranty information is located on the

back of this manual.

Suggested Service Parts List

DESCRIPTION

PART NUMBER

Belt

11031

Brush Bearing

09019

Cord Assembly (USA/Japan) 23572

230V Cord Assembly (Europe)

23178

Dome Assembly

28034

Dome Gasket

35060

Hose Cuff. Short Blue

27508

Hose Cuff. Longer Blue

27354

Hose Cuff, White

27079

Jet Assembly

44055

Jet

44061

Jet Seal

44051

Jet Body w/Seal

44052

Manifold Assembly

54094

Pump Service Kit

47176

Screen/Filter, Dome

34140

Screen/Filter, Solution Tank

73250

Solution Release Cable

27665

Solution Release Lever

51200

Switch

72074

230V Switch

72121

Valve

84134

Dailv Maintenance:

These procedures are followed at the end of
each work period to extend the life of the ma-
chine.

1.)

2.)

5.)

6.)

7.)

Empty unused cleaning solution by
disconnecting clear hose on back of
machine and pouring into floor drain.

Inspect and clean solution filter screen
inside tank and vac intake screen

inside dome.

Flush the system. Fill solution tank

with 1 or 2 gallons (4 8 liters) of clean
hot water. With machine over floor
drain turn on vac/pump switch until
solution tank is empty.

Inspect spray pattern of jets.
Remove jets and rinse if clogged.

each use, rinse recovery tank with

fresh water. Periodically inspect the

recovery tank and decontaminate if
necessary, using a Hospital Grade

Virucide or a l-l 0 bleach to water
solution. Waste water should be disposed
of properly.

Remove any lint or debris from brush.

Inspect power cord. Remember, this

cord will lay on a damp surface.

Warning:

IMMEDIATELY REPLACE WORN OR
FRAYED POWER CORDS.

8.)

Inspect hoses. Worn or cracked
hoses may cause loss of vac pressure.

9.)

Place the brush in the storage
position. Press back slightly on the
main handle, and place the brush
adjustment lever in the

For infrequent use or long periods of stor-

age,

flush the system with a neutralizing solution

of 1 quart (1 liter) white vinegar mixed with 2 gal-
lons (8 liters) hot water. Flush the system with
clean hot water after neutralizing.

8

Advertising
This manual is related to the following products: