Operation

To change settings, from
either the full-body spray
or the concentrated power
spray, push the spray
change button at the base
of the showerhead so it
extends to the opposite side
of its current position.

Flow Control

Waterpik

®

brand showerheads are equipped with an OptiFLOW

®

regu-

lator that limits maximum water flow to 2.5 gallons per minute at 80
psi as mandated by U.S. federal law.
In areas with extremely low water pressure, causing
the shower water flow to be unsatisfactory, the
flow regulator may be removed to improve
the water flow in the showerhead.
To remove, unscrew
filter screen by turning
counterclockwise.
Remove regulator
with needle-nose
pliers and replace
filter screen.

1. Remove old showerhead. Clean pipe threads

thoroughly.

2. Tighten the flexible shower arm onto the

“J” pipe by hand, applying force to
the nut closest to the “J” pipe.
Do not use the flexible shower
arm as a handle to tighten this
connection.

3. Attach the showerhead to the

flexible shower arm by hand
tightening the shower arm collar to the
threaded end of the shower head.

4. Be sure to properly align threads before tightening.
5. Slowly turn on cold water and check for leaks. If leaks occur,

retighten all connections.

6. Do not use excessive force in positioning the showerhead and/or

arm.

7. If the showerhead is not maintaining its position, re-tighten the

showerhead collar and shower arm nut.

Hand-Held Installation

1. Remove old showerhead. Clean pipe threads thoroughly.
2. Slightly loosen swivel collar on bracket.
3. Hand tighten pivot ball to pipe.
4. Hand tighten adaptor to showerhead.
5. Hand tighten hose to adapter and bracket.
6. Place showerhead in bracket.

Instruction Manual

drenching rain showerhead

Flexible Installation

Your new showerhead will fit a standard 1/2” shower “J” pipe. Do not
attach this product to a plastic shower arm since it may not provide
adequate support.
Tools are not required. Do not use pipe tape or any other sealants
when installing the showerhead. These materials are not necessary
and may cause the nut to loosen prematurely. Hand tightening is
sufficient to secure the shower thread. Make sure the washer is in the
end of the nut.

DATE: 18 May 2010 CLIENT: Water Pik, Inc.
FILENAME: FN20010910-FAD_Cascadia.indd

DESCRIPTION: Waterpik Cascadia Showerhead Instruction Manual

FILE TYPE: Adobe InDesign CS4

PREPARED BY: Brian Colon

FORM: 20010910-F AD

SIZE FLAT: 8.375” x 8.5”

SIZE FOLDED: 2.8125” x 4.25”

FOLDS: Indicated

DIELINE: N/A

INK: Black

NOTES:

Troubleshooting Guide

Problem

Solution

No water flow from

installed shower

head:

a Confirm previous shower washer is not in the

j-pipe.

b Confirm the hose is properly installed, try

switching ends.

c Confirm there is only one washer in the pivot ball.

Low water pressure

or missing spray

patterns

a Clean shower head in vinegar/water solution.

(See care section).

b Clean screen and flow regulator.

Leaking at pipe pivot

ball connection:

a Confirm one single washer is seated on top of

the screen.

b Grate bar of soap across the j-pipe threads to act

as a sealant.

Showerhead and/

or bracket stiff to

change angle

a Immerse pivot ball and large nut of the bracket in

hot water or use a blow dryer for several minutes

and then use a towel to loosen the large nut.

For Fixed Mount: install FM shower head to

provide additional leverage to change angle of

spray. (Contact Waterpik for further assistance).

Care and Cleaning

Clean the filter screen at least once a year, or when you notice a drop in

water pressure. To remove, unscrew the nut from the pipe. Remove the

screen by turning it counter-clockwise (pliers may be used) and rinse.
If you remove the flow regulator, be sure you reinstall it with the black

O-ring facing out.
• Cleaning is required when mineral deposits appear on the spray

holes to maintain proper working conditions.

• Clean the flexible nozzles by rubbing with a finger or soft bristled

toothbrush. Clean by soaking in household vinegar.

• Do not clean or rinse any part with harsh chemicals, heavy-duty

cleaners or abrasives. This may damage parts or finish and may void

the warranty.

Limited Lifetime Warranty

Water Pik, Inc. warrants to the original purchaser of this product that it is

free from defects in material and workmanship for as long as the original

purchaser owns this product. Water Pik, Inc. will replace any part of the

product which in our opinion is defective, provided that the product has

not been abused, misused, altered or damaged after purchase. (This

includes damage due to use of tools or harsh chemicals.) In the event

an item has been discontinued we will replace with what we deem to be

the closest product. Water Pik, Inc. is not responsible for labor charges,

installation, or other consequential cost. The responsibility of Water Pik,

Inc. shall not exceed the original purchase price of the product. This

warranty gives you specific legal rights. You may also have other rights

that vary where you reside. Save your receipt as proof of purchase is

required for warranty action.

Have any questions or need assistance?

If in the U.S., call our toll-free
Customer Assistance Line,
1-800-525-2774
www.waterpik.com

If outside the U.S., write us at:
Water Pik, Inc.
1730 East Prospect Road
Fort Collins, CO 80553-0001 USA

Waterpik

®

(stylized) is a trademark of Water Pik, Inc. registered in the EU,

Switzerland, Mexico, Canada, and United States.
Waterpik

®

is a trademark of Water Pik, Inc. registered in Argentina, Australia,

Austria, Canada, China, Czech Republic, Hungary, India, Japan, Poland, Russian
Federation, South Africa, Switzerland, Ukraine, and the United States.
Cascadia

®

is a trademark of Water Pik, Inc. registered in Australia, Canada, EU,

Switzerland and the United States.
Optiflow

®

is a trademark of Water Pik, Inc. registered in Australia, Canada, the EU,

Korea and the United States.
© 2010 Water Pik, Inc.

Water Pik, Inc.
1730 East Prospect Road, Fort Collins, CO 80553-0001 USA
www.waterpik.com

FN 20010910-F AD

Nut

Flow Regulator

(black O-ring

faces out)

Washer

Filter Screen

Filter

Screen

Flow Regulator

Spray Change Button

Spray Change Button

Shower

Arm Nut

Adapter

Spray Change

Button

5’ hose

Models:

CF-200
CF-201

CF-201C
CF-203C
CF-209C

CF-261

CF-263C

Collar

Flexible Arm

Spray Change

Button

Bracket

Advertising
This manual is related to the following products: