White Rodgers 755-1 User Manual

White Rodgers Water boiler

Advertising
background image

To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.

Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation.

Following installation or replacement, follow
appliance manufacturers’ recommended instal-
lation/service instructions to insure proper op-
eration.

PART NO. 37-5787A

9722

Printed in U.S.A.

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

WHITE-RODGERS

754-1, 755-1, 756-1

Electric Water Heater Control

INSTALLATION INSTRUCTIONS

This control is designed to meet the high electrical capac-
ity requirements of electric water heaters.

The temperature control is a normally closed switch
which opens on a rise in temperature. The SPST version
(755-1) will control one heating element. The SPDT
version (756-1) will control two heating elements when
used with W-R type 755-1. (See wiring diagrams.)

Operator: Save these instructions for future use!

PRECAUTIONS

THIS CONTROL MUST BE INSTALLED BY A QUALI-
FIED INSTALLER.

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

This control has been accurately calibrated at the factory.
Any attempt to re-calibrate this control will void the White-
Rodgers warranty.

Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage control and
could cause shock or fire hazard.

If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a quali-
fied heating and air conditioning contractor or a
licensed electrician.

CAUTION

!

The limit control (754-1) is a normally closed DPST switch
which opens on a rise in temperature to limit the maximum
allowable temperature. It has manual reset.

Both switches are calibrated to meet the requirements for
typical residential type storage tank water heaters.