Wayne-Dalton 3994-433 User Manual

Radio receiver

Advertising
background image

1

4

3

2

Preliminary Operator Tests:

1. Make sure door or gate
operator has been properly
installed in accordance with
unit’s installation instructions.

2. Test and confi rm proper
operation of the door or gate
operator before proceeding with
the installation of this receiver.

WARNING: Keep
fi ngers and other body
parts away from all
moving parts of the
door and gate
operators system
while the system is
being operated.

WARNING: To prevent
unintended operation,
disconnect power to
the door or gate
operator after
completing the above
preliminary operator
tests.

Models: 3990-372, 3994-433

Installation Instructions
and Owner’s Manual

Radio Receiver

Warning

Defi nition of Symbol

Radio Receiver Specifi cations

Operating Temperature Range:.........................-22 F to 160 F
IP (Ingress Protection, International Protection):.... IP20

NOTICE: Dry Locations Only

INPUT

POWER

Non-polarized input connection.
10 to 28 VDC, 40 mA with relay off, 60 mA with relay active
10 to 28 VAC, 40 mA with relay off, 90 mA with relay active

NOTICE: Class 2 product, for voltages 32 VAC/DC or less

RELAY OUTPUT CONTACTS

Normally-open, dry contacts, non-polarized connection.
Switching current capability:1.0 mA to 0.5 A at 10 to 28 VAC and 2.0 mA to
1.0 A at 10 to 28 VDC

RF Center Frequency:............................. Model 3990-372, 372.5 MHz.
Model

3994-433,

433.92

MHz.

Antenna length:....................................... Model 3990-372, 7.2 inch
Model

3994-433,

5.8

inch

Capable of learning 14 transmitters (any combination of portable
transmitters, RF wall-stations or RF keypads).

Installation Safety Precautions

WARNING: INCORRECT INSTALLATION CAN LEAD
TO SEVERE OR FATAL INJURY. FOLLOW THESE
INSTRUCTIONS CAREFULLY.

READ and FOLLOW all installation instructions.

1. Before installing this receiver, read the door or gate operator’s instruction

manual fully, so you are aware of all of the unit’s functions and features.

2. Wear protective gloves to install, repair, or adjust door, gate, or operator

to avoid hand injuries.

3. Wear eye protection when using tools to install, repair, or adjust door,

gate, or operator to prevent eye injuries.

4. Mount control buttons within sight of door or gate, at a minimum height

of 5 ft, so small children cannot reach them. Keep control buttons away
from all moving parts of a door and at least 6 ft away from all moving
parts of a gate or its operator.

5. Before installing receiver, disconnect all power to door or gate operator

to prevent unintended operation.

6. Do not connect this receiver to a power source until instructed to do so.

Do not reconnect power to the door or gate operator until instructed to
do so.

7. Only install receiver on a properly functioning door or gate operator.

8. Installation and wiring must comply with local building and electrical

codes. This product is not intended and must not be installed in a explo-
sive environment.

9. Pay close attention to all warnings, notices, and notes in these
instructions.

10. To prevent electrical shock and/or fi re hazards, do not connect this

receiver to any voltages greater than 32 VAC or DC.

WARNING: After installing and testing this receiver, test
all safety features of your door or gate’s operator.

Disconnect this receiver if any of your door or gate’s safety
system features fail to function properly. Then have your door
or gate operator serviced immediately by a qualifi ed person.

You can reach us Toll Free 1-888-827-3667 for Consumer Assistance or online at www. wayne-dalton.com

Mounting:

WARNING: Do not
connect electrical
power to this receiver
until instructed to do
so.

WARNING: Disconnect
electric power to door
or gate operator before
making repairs or
removing case
covers.

1. Select a location four to six feet
from other receivers. Receiver
can be attached to metal, wood,
or plastic surfaces.

2. Use screws or other fastening
means to attach receiver.

3. If receiver is mounted inside a
metal enclosure, use an antenna
extension kit (optional) to extend
the antenna outside of the
enclosure.

Package Contents:

1. Receiver
2. Antenna
3. Twin-lead wire, 6 feet
4. Manual

Optional Accessories:

1. Power Adapter
2. Antenna Extension Kit

Wiring:

1. Disconnect power to the door
or gate operator before
proceeding.

WARNING: To prevent
electrical shock, be
sure electrical power is
disconnected before
proceeding with wiring.

2. Connect the enclosed twin-lead
wires to the terminals labeled
RLY. (use only 22 AWG or larger;
CL2X or better)

3. Connect other end of twin-lead
wires to door or gate opener’s
control input.

4. Connect power to the two
terminals labeled PWR. Receiver
requires 10V to 28V AC or DC.

PWR

PWR

RLY

RLY

NON-POLARIZED

Power

Supply

10V - 28V

AC/DC

Door or Gate

control input

© Copyright 2007 Wayne-Dalton Corp.

Part No.318705

Rev 3 7/9/2007

P.O. Box 67 Mt. Hope, OH 44660

(888) 827-3667

Connect Antenna:

Direct Connect Antenna: Attach
antenna as shown. For best
reception keep antenna wire
straight and away from metal
objects.

Antenna Extension Kit
(Optional):

1. Connect extension wire to
receiver.

2. Route wire outside metal
enclosure. Route and secure wire
away from moving parts.

3. Mount antenna holder outside
enclosure.

4. Screw antenna to extension
wire.

NOTICE: Do not route coax wire
near any moving parts of the
operator. If necessary, secure
coax wire away from any moving
parts.

5. Position antenna wire straight.
For best reception, keep antenna
away from metal.

IMPORTANT NOTICE!

Read the enclosed instructions carefully before installing this radio receiver.
Pay close attention to all warnings and notes. This manual should be
retained for future reference.

1.

2.

Advertising
This manual is related to the following products: