Zyliss CompleteStat-Series CS9B-THO User Manual

Completestat-series environmental controllers

Advertising
background image


Model CS9B-THO and CS9BE-THO Shown


4 Models:

CS9B-THO

Temperature, Humidity, Occupancy

CS9B-THOC

Temperature, Humidity, Occupancy, and CO2

CS9BE-THO

Temperature, Humidity, Occupancy w/Ethernet Connection

CS9BE-THOC Temperature, Humidity, Occupancy, and CO2 w/Ethernet Connection


Features---All Models except as Noted:

All-in-One Multi-Function Controllers: THO models: Temperature, Humidity (dehumidification only), Occupancy

THOC models: Temperature, Humidity (dehumidification only), Occupancy and CO2 (On/Off control)

Adaptive Occupancy Scheduling:

1. Automatically learns the start of the 1

st

persistent occupancy for each day of the week using on-

board motion sensor to create a 7-day start of occupancy schedule

2. Continuously adapts the schedule with any changes to the usage pattern

3. Provides adaptive optimized space warm-up or cool-down with respect to the learned start of

occupancy for each day

User-friendly, high contrast, backlit LCD display with Continuous “On” option

Simple 5-Button user interface for menu-driven configuration and operation

No need for connected PC or programming

All models are BACnet capable for MS/TP, EIA-485 using shielded twisted pair for networking

BACnet is an ANSI and ISO global standard open communications protocol developed by ASHRAE

The “E” Ethernet versions offer alternate method of networking using CAT 5 port on the sub-base

9-relay output for complete and reliable HVAC system control

F or C temperature option

Conventional modes: 1H/1C, 2H/2C, 1H/2C, 2H/1C, 2H/3C if configured for economizer

Heat Pump modes: 1-Stage (2H/1C), 2-Stage (3H/2C, 3H/3C if configured for economizer)

Wide Range Occupancy Sensor: senses up to 33 feet distance, 120-degree horizontal and 100-degree vertical
sensing from controller location. Remote occupancy sensor(s) can be added for extreme applications

Built-in alarms and trend logs

Configurable password protection with 3 levels of password-protected access

Programmable (7-day, 5+2, individual days, up to 12 holidays) or non-programmable

No batteries, retains date/time settings for 72-hours during power loss

All settings except time maintained permanently in non-volatile memory until changed by user

Auto or manual changeover option

Fan Operation: Auto/On/Programmed (Programmed is On during Occupied, Auto during Un-Occupied)

Form No

F1943-512

Supersedes

F1943-212

Page

1 of 2

CompleteStat-Series Environmental Controllers

THO Models (Temperature, Humidity and Occupancy)

THOC Models (Temperature, Humidity, Occupancy and CO2)