Rear panel connections, Controls and connections 12 user’s guide, Monitor out connections – Yamaha MT4X User Manual

Page 14: Stereo out connections, Mic/line input connections, Aux return (1, 2) connections, Aux send (1, 2) connections, Tape out (1 to 4/sync) connections

Advertising
background image

Controls and Connections

12

User’s Guide

Rear Panel Connections

f

MONITOR OUT
connections

Output impedance: 1 k

Nominal output level:

-10 dB (at 10 k

load)

These RCA/Phono connectors
are used to plug in a monitor
amplifier or powered
loudspeakers. The same signal
which is output from the
PHONES connector (

d

) is also

output from these connectors.

AUX RETURN

2

L/MONO

1

L/MONO

STEREO OUT

L

R

MONITOR OUT

L

R

TAPE OUT

3

1

2

SYNC/4

AUX SEND

1

2

MIC/LINE INPUT

3

1

2

4

R

R

g

f

h

i

j

k

g

STEREO OUT connections

Output impedance: 1 k

Nominal output level: -10 dB (at 10 k

load)

These RCA/Phono connectors are used to output the final stereo mixdown to the master recorder —
typically, a stereo tape deck.

h

MIC/LINE INPUT connections

Input impedance: 10 k

Nominal input level: -10 dB to -50 dB
These 1/4” phone connectors are used to input microphones, electronic instruments, and line-level
sources.

i

AUX RETURN (1, 2) connections

Input impedance: 10 k

Nominal input level: -10 dB (AUX RETURN - LEVEL control nominal)
These 1/4” phone connectors are used to input the signals from external effects devices and other
signal processors. If the external device is monaural, plug it into one of the L/MONO connectors.

j

AUX SEND (1, 2) connections

Output impedance: 1 k

Nominal output level: -10 dB (at 10 k

load)

These 1/4” phone connectors are used to output signals to external effects devices and other signal
processors.

k

TAPE OUT (1 to 4/SYNC) connections

Output impedance: 1 k

Nominal output level: -10 dB (at 10 k

load)

These RCA/Phono connectors are used to output the individual tracks directly from the recorder
section of the MT4X.

Advertising