Front panel – Yamaha NHB32-C User Manual

Page 30

Advertising
background image

26

NHB32-C Network Hub & Bridge

ACU16-C & NHB32-C Owner’s Manual

Front Panel

A

USB port
This USB port is used to connect the NHB32-C to a USB port on a PC running Net-
workAmp Manager. The rear panel TO COMPUTER port offers an alternative method of
connection. The PC port to be used for communication with the NHB32-C is set in Net-
workAmp Manager.

B

UNIT ID switch
This switch is used to set the unit ID of the NHB32-C. Each NHB32-C on the network must
be assigned an exclusive ID from 0 to 7. The following table shows how the switch markings
correspond to unit IDs 0 through 7. The switch can be set by using either a small flat-bladed
screwdriver or a Phillips screwdriver.

C

LOCK indicator
This indicator lights up when the NHB32-C is locked to the selected wordclock source. It
flashes when the NHB32-C is unlocked.

D

NETWORK STATUS indicators
These indicators show the status of the CobraNet network.

LINK: This indicator lights when the NHB32-C has a valid connection to the CobraNet
network. If a link cannot be established, the CONDUCT and ERROR indicators light
instead.

CONDUCT: This indicator lights when the NHB32-C is the CobraNet Conductor (i.e.,
wordclock master and arbitrator for the entire network).

ERROR: This indicator lights when a CobraNet link cannot be established, and flashes
when a CobraNet interface error occurs.

E

Wordclock source indicators
These indicators show the currently selected wordclock source.

AES/EBU: Wordclock sourced from a pair of AES/EBU inputs.
NETWORK: Wordclock sourced from the CobraNet network.
WORD CLOCK IN: Wordclock sourced from the NHB32-C’s BNC WORD CLOCK IN
connector.

Unit ID

0

1

2

3

4

5

6

7

Switch Setting

0/8

1/9

2/A

3/B

4/C

5/D

6/E

7/F

Note: The NHB32-C must be turned off before setting the unit ID. Make sure that each
NHB32-C is assigned an exclusive ID. Assigning the same unit ID to two or more NHB32-Cs
will produce unpredictable results.
Note: Use a screwdriver that’s appropriate for the size of the slot in the switch. Using a screw-
driver with too big a handle, or a screwdriver with too small a tip, may damage the switch.

Note: If a system error occurs, the LINK, CONDUCT, and ERROR indicators flash simulta-
neously. This type of error can be caused by an incorrect device setting or a faulty NHB32-C.
See “System Errors” on page 37 for more information.

88

NETWORK HUB AND BRIDGE

LINK

CONDUCT

LOCK

ERROR

1 2 3

5

6 7

8 9 J

K

4

Advertising