Installation –

Mounting Height & Clearance

6

www.zephyronline.com

DUCTING

A minimum of 6” round or 3-1/4 x 10” rectangular
GXFWPXVWEHXVHGWRPDLQWDLQPD[LPXPDLUÀRZ
HI¿FLHQF\

Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR

Use calculation worksheet to compute total duct
work.

ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 6” to 7” or 8”.

If turns or transitions are required: Install as far
away from opening and as far apart, between 2,
as possible.

Minimum mount height between range top to hood
bottom should be no less than 28”.

Maximum mount height should be no higher than
36”.

It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORRVHLWVSHUIRUPDQFHDQGHI¿FLHQF\

If available, also refer to range manufacturer’s
height clearance requirements and recommended
hood mounting height above range. Always check
your local codes for any differences.

Mounting Height (Recirculating)
Minimum Ceiling Height 8’. Hood mounted 28”
DERYHFRRNLQJVXUIDFH´IURPÀRRU
Maximum Ceiling Height 9’3”. Hood mounted 36”
DERYHFRRNLQJVXUIDFH´IURPÀRRU

Mounting Height (Ducted)
¶´+RRGPRXQWHG´DERYHFRRNLQJVXUIDFH
´IURPÀRRU

Duct cover extension kit available for ceiling
heights up to 12 feet. Turn to page 16 for part
number and ordering information.

DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before

installation.

• If the unit is damaged in shipment, return the

unit to the store in which it was bought for
repair or replacement.

• If the unit is damaged by the customer, repair

or replacement is the responsibility of the
customer.

‡ ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHU LIRWKHU

WKDQWKHFXVWRPHU UHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer
and installer.

min. ducted 28”
min. recirc. 32“
max. 39”

min. ducted 92” (7’8“)
min. recirc. 96” (8’)
max. 111” (9’3”)

min. 28”
max. 36”

36”

4”

Note: Bottom duct covers may be cut down by 4” to expose top duct cover louver holes.
This may be necessary if the customer is recirculating the hood, has an 8’ ceiling and
wants the hood mounted between 29 - 32 inches above the cooking surface.