INSTALLATION

FORM 115.20-NOM2 (105)

RECEIVING

Material in this shipment has been inspected at the

factory and released to the transportation agency in

good condition. When received, a visual inspection of

all cartons should be made immediately. Any evidence

of rough handling or apparent damage should be noted

on the delivery receipt and the material inspected in the

presence of the carrier's representative.

If damage is found, a claim should be

filed against the carrier immediately.

STORAGE

If the equipment is not to be immediately installed, store

it in a dry location with the motor protected against

moisture, dust, corrosion and physical damage.

PREPARE CEILING FOR MOUNTING

Depending upon building construction, provisions

for mounting the unit must be made by the contractor

according to architects; drawings.

It is important to ensure that the fan coils are securely

mounted and the structure is sufficient to support the

weight of the equipment. All anchors for mounting the

equipment must be placed and sized to ensure a safe

and durable installation.

The YHBC, YPHBC, YRHBC, YHH, YHHS, YPHH,

YHYB, and YPHYB units are designed for installation

in a horizontal position above a dropped ceiling. The

YCHBC is a cabinet unit intended for horizontal

exposed surface mounting.

Unit must not be operated during

building construction due to ex-

cessive airborne dust and debris. The

units must not be operated under any

circumstances without an air filter in

place.

WIRING

All wiring must comply with the local and national code

requirements. Units are provided with wiring diagrams

and nameplate data to provide information required for

necessary field wiring.

For power wiring a 4 x 4 electrical box is provided on

the cabinet for connection of power supply and is located

on the same side as piping.

On YHBC units, the box is shipped unattached, it is

field attached to the unit in a location convenient to

electrical entrance.

Any devices such as fan switches or

thermostats that have been furnished

by the factory for field installation

must be wired in strict accordance

with the wiring diagram that is sup-

plied with the unit. Failure to do so

could result in damage or injury.

In free (non-ducted return air) return installations of

YHBC, YHH, YHHS and YHYB units; the furred

down area must be completely sealed (except return

air grille) to ensure that all return air is pulled from

the conditioned space and not from other areas of the

building structure.

Access must be provided for servicing the unit. If

this access is provided by a removable ceiling panel,

ample space must be allowed for removal of the blower

panel and to provide access to electrical and plumbing

controls.