Exit setup mode – Zebra 105SL User Manual

Page 83

Advertising
background image

75

Configuration

Setup Mode

6/30/06

105SL User Guide

11342L-001 Rev. A

Exit Setup Mode

To leave Setup mode, complete these steps:

1.

Press

SETUP/EXIT

.

The LCD displays

SAVE CHANGES

.

2.

Press

PLUS (+)

or

MINUS (-)

to display the save options (

Table 8

).

3.

Press

NEXT/SAVE

to select the displayed choice.

When the configuration and calibration sequence is done,

PRINTER READY

displays.

Table 8 • Save Options When Leaving Setup Mode

LCD

Description

PERMANENT

Stores values in the printer even when power is turned off.

TEMPORARY

Saves the changes until power is turned off.

CANCEL

Cancels all changes made since you entered Setup mode,
except for changes made to the darkness and tear-off settings,
which go into effect as soon as they are made.

LOAD DEFAULTS

Restores all parameters other than the network settings back to
the factory defaults. Use care when loading defaults because
you will need to reload all settings that you changed manually.

Note •

Loading factory defaults causes the printer to

auto-calibrate.

LOAD LAST SAVE

Loads values from the last permanent save.

DEFAULT NET

Restores the wired and wireless network settings back to
factory defaults.

Advertising