Effect parameter list, Parameters marked with a – Yamaha PLG100-XG User Manual

Page 20

Advertising
background image

20

Effect Parameter List

Parameters marked with a

in the “Control” column can be controlled from an AC1 (assignable controller 1) etc.

However, this is valid only for a Variation effect (when selected for Insertion).

HALL1,HALL2
ROOM1,ROOM2,ROOM3
STAGE1,STAGE2
PLATE (reverb, variation block)

WHITE ROOM
TUNNEL
BASEMENT (reverb block)

DELAY L,C,R (variation block)

DELAY L,R (variation block)

ECHO (variation block)

CROSS DELAY (variation block)

EARLY REF1,EARLY REF2(variation block)

GATE REVERB
REVERSE GATE (variation block)

No.

Parameter

Display

Value

See Table

Control

1 Reverb Time

0.3 - 30.0s

0 - 69

table#4

2 Diffusion

0 - 10

0 - 10

3 Initial Delay

0.1 - 99.3ms

0 - 63

table#5

4 HPF Cutoff

Thru - 8.0kHz

0 - 52

table#3

5 LPF Cutoff

1.0k - Thru

34 - 60

table#3

6
7
8
9

10 Dry/Wet

D63>W - D=W - D<W63

1 - 127

11 Rev Delay

0 - 63

0 - 63

table#5

12 Density

0 - 3

0 - 3

13 Er/Rev Balance

E63>R - E=R - E<R63

1 - 127

14
15 Feedback Level

-63 - +63

1 - 127

16

No.

Parameter

Display

Value

See Table

Control

1 Reverb Time

0.3 - 30.0s

0 - 69

table#4

2 Diffusion

0 - 10

0 - 10

3 Initial Delay

0.1 - 99.3ms

0 - 63

table#5

4 HPF Cutoff

Thru - 8.0kHz

0 - 52

table#3

5 LPF Cutoff

1.0k - Thru

34 - 60

table#3

6 Width

0.5 - 10.2m

0 - 37

table#8

7 Heigt

0.5 - 20.2m

0 - 73

table#8

8 Depth

0.5 - 30.2m

0 - 104

table#8

9 Wall Vary

0 - 30

0 - 30

10

11 Rev Delay

0 - 63

0 - 63

table#5

12 Density

0 - 3

0 - 3

13 Er/Rev Balance

E63>R - E=R - E<R63

1 - 127

14
15 Feedback Level

-63 - +63

1 - 127

16

No.

Parameter

Display

Value

See Table

Control

1 Lch Delay

0.1 - 715.0ms (variation block)

1 - 7150

2 Rch Delay

0.1 - 715.0ms (variation block)

1 - 7150

3 Cch Delay

0.1 - 715.0ms (variation block)

1 - 7150

4 Feedback Delay

0.1 - 715.0ms (variation block)

1 - 7150

5 Feedback Level

-63 - +63

1 - 127

6 Cch Level

0 - 127

0 - 127

7 High Damp

0.1 - 1.0

1 - 10

8
9

10 Dry/Wet

D63>W - D=W - D<W63

1 - 127

11
12
13 EQ Low Frequency

50Hz - 2.0kHz

8 - 40

table#3

14 EQ Low Gain

-12 - +12dB

52 - 76

15 EQ High Frequency 500Hz - 16.0kHz

28 - 58

table#3

16 EQ High Gain

-12 - +12dB

52 - 76

No.

Parameter

Display

Value

See Table

Control

1 Lch Delay

0.1 - 715.0ms (variation block)

1 - 7150

2 Rch Delay

0.1 - 715.0ms (variation block)

1 - 7150

3 Feedback Delay 1

0.1 - 715.0ms (variation block)

1 - 7150

4 Feedback Delay 2

0.1 - 715.0ms (variation block)

1 - 7150

5 Feedback Level

-63 - +63

1 - 127

6 High Damp

0.1 - 1.0

1 - 10

7
8
9

10 Dry/Wet

D63>W - D=W - D<W63

1 - 127

11
12
13 EQ Low Frequency

50Hz - 2.0kHz

8 - 40

table#3

14 EQ Low Gain

-12 - +12dB

52 - 76

15 EQ High Frequency 500Hz - 16.0kHz

28 - 58

table#3

16 EQ High Gain

-12 - +12dB

52 - 76

No.

Parameter

Display

Value

See Table

Control

1 Lch Delay1

0.1 - 355.0ms (variation block)

1 - 3550

2 Lch Feedback Level -63 - +63

1 - 127

3 Rch Delay1

0.1 - 355.0ms (variation block)

1 - 3550

4 Rch Feedback Level -63 - +63

1 - 127

5 High Damp

0.1 - 1.0

1 - 10

6 Lch Delay2

0.1 - 355.0ms (variation block)

1 - 3550

7 Rch Delay2

0.1 - 355.0ms (variation block)

1 - 3550

8 Delay2 Level

0 - 127

0 - 127

9

10 Dry/Wet

D63>W - D=W - D<W63

1 - 127

11
12
13 EQ Low Frequency

50Hz - 2.0kHz

8 - 40

table#3

14 EQ Low Gain

-12 - +12dB

52 - 76

15 EQ High Frequency 500Hz - 16.0kHz

28 - 58

table#3

16 EQ High Gain

-12 - +12dB

52 - 76

No.

Parameter

Display

Value

See Table

Control

1 L->R Delay

0.1 - 355.0ms (variation block)

1 - 3550

2 R->L Delay

0.1 - 355.0ms (variation block)

1 - 3550

3 Feedback Level

-63 - +63

1 - 127

4 Input Select

L,R,L&R

0 - 2

5 High Damp

0.1 - 1.0

1 - 10

6
7
8
9

10 Dry/Wet

D63>W - D=W - D<W63

1 - 127

11
12
13 EQ Low Frequency

50Hz - 2.0kHz

8 - 40

table#3

14 EQ Low Gain

-12 - +12dB

52 - 76

15 EQ High Frequency 500Hz - 16.0kHz

28 - 58

table#3

16 EQ High Gain

-12 - +12dB

52 - 76

No.

Parameter

Display

Value

See Table

Control

1 Type

S-H, L-H, Rdm, Rvs, Plt, Spr

0 - 5

2 Room Size

0.1 - 7.0

0 - 44

table#6

3 Diffusion

0 - 10

0 - 10

4 Initial Delay

0.1 - 99.3ms

0 - 63

table#5

5 Feedback Level

-63 - +63

1 - 127

6 HPF Cutoff

Thru - 8.0kHz

0 - 52

table#3

7 LPF Cutoff

1.0k - Thru

34 - 60

table#3

8
9

10 Dry/Wet

D63>W - D=W - D<W63

1 - 127

11 Liveness

0 - 10

0 - 10

12 Density

0 - 3

0 - 3

13 High Damp

0.1 - 1.0

1 - 10

14
15
16

No.

Parameter

Display

Value

See Table

Control

1 Type

TypeA,TypeB

0 - 1

2 Room Size

0.1 - 7.0

0 - 44

table#6

3 Diffusion

0 - 10

0 - 10

4 Initial Delay

0.1 - 99.3ms

0 - 63

table#5

5 Feedback Level

-63 - +63

1 - 127

6 HPF Cutoff

Thru - 8.0kHz

0 - 52

table#3

7 LPF Cutoff

1.0k - Thru

34 - 60

table#3

8
9

10 Dry/Wet

D63>W - D=W - D<W63

1 - 127

11 Liveness

0 - 10

0 - 10

12 Density

0 - 3

0 - 3

13 High Damp

0.1 - 1.0

1 - 10

14
15
16

Advertising