Midi data format – Yamaha PLG100-XG User Manual

Page 28

Advertising
background image

28

MIDI Data Format

1.2.22 RPN (Registered parameter number)

This message is used to specify part parameters such as Pitch Bend Sensitivity
or Tuning etc. as an offset value.
Use RPN MSB and RPN LSB to specify the parameter that you wish to mod-
ify, and then use Data Entry (see 1.2.4) to set the value of the specified param-
eter.

Control#

Parameter

Data Range

100

RPN LSB

0...127

101

RPN MSB

0...127

If the Multi Part parameter Rcv RPN = OFF, that part will not receive this mes-
sage.

The following RPN messages can be received.

*1 Refer to 1.2.4
*2 '--' indicates that the setting value is ignored.

1.2.23 Assignable controller

By assigning a control change number of 0...95 to a part, the specified effect
can be controlled.
This device allows two control change numbers (AC1 and AC2) to be specified
for each part.
The following parameters specify the effect of AC1 and AC2.

• Multi Part Parameter

1. AC1, AC2 PITCH CONTROL
2. AC1, AC2 FILTER CONTROL
3. AC1, AC2 AMPLITUDE CONTROL
4. AC1, AC2 LFO PMOD DEPTH
5. AC1, AC2 LFO FMOD DEPTH
6. AC1, AC2 LFO AMOD DEPTH

• Effect1 Parameter

7. AC1, AC2 VARIATION CONTROL DEPTH

(Valid if Variation Effect is assigned to a part as Insertion)

The AC1 control change number is specified by the Multi Part parameter AC1
CONTROLLER NUMBER, and the AC2 control change number is specified
by the Multi Part parameter AC2 CONTROLLER NUMBER.

1.3 Channel mode messages

These messages specify the basic operation of a part.

1.3.1 All Sound Off

This message silences all currently-sounding notes on the corresponding chan-
nel.
However, the settings of channel messages such as Hold 1 and Sostenuto will
be maintained.

Control#

Parameter

Data Range

120

All Sound Off

0

1.3.2 Reset All Controllers

This message resets the following controllers to their default values.

The following data is not changed
Parameter values specified by program change, bank select MSB/LSB, vol-
ume, pan, effect send levels 1, 3, 4, RPN and NRPN.

Control#

Parameter

Data Range

121

Reset All Controllers

0

1.3.3 All Note Off

This message turns off all notes which are currently on for the corresponding
part.
However, if Hold 1 or Sostenuto are on, notes will continue to sound until
these are turned off.

Control#

Parameter

Data Range

123

All Note Off

0

1.3.4 Omni Off

Perform the same processing as when All Note Off is received.

Control#

Parameter

Data Range

124

Omni Off

0

1.3.5 Omni On

Perform the same processing as when All Note Off is received.

Control#

Parameter

Data Range

125

Omni On

0

1.3.6 Mono

Perform the same processing as when All Sound Off is received, and if the
value (mono number) is in the range of 0...16, set the corresponding channel to
Mode4* (m = 1).

Control#

Parameter

Data Range

126

Mono

0...16

* Mode4 is a state in which only channel messages on the specified

channel will be received, and notes will be sounded individually
(monophonically).

1.3.7 Poly

Perform the same processing as when All Sound Off is received, and set the
corresponding channel to Mode3*.

Control#

Parameter

Data Range

127

Poly

0

* Mode3 is when channel messages will be received only on the speci-

fied channel, and will be sounded polyphonically.

1.4 Program change

This message reports sound selection changes and changes the program num-
ber of the receiving channel.
In order to include changes to the voice bank, Program Change and Bank
Select messages must be sent as a set (see 1.2.1).
When RevPROGRAM CHANGE=OFF for Multi Part Parameter, the program
change for that part is not received.

RPN

MSB LSB

Data Entry

*1

MSB LSB

Parameter name and value range

00

00

mm

-- *2

Pitch bend sensitivity

mm: 00-24 (0...+24 semitones)
Specify up to 2 octaves in semitone steps

00

01 mm

ll

Fine

tuning

mm

ll: 00

00

-100 cents

:

:

mm

ll: 64

00

0 cents

:

:

mm

ll: 127 127

+100 cents

[Note] mm ll: 00

127 (=-87.5) cents is

followed by 01 00 (=-87.4) cents.

00

02 mm

--

Coarse

tuning

mm: 40 - 64 - 88 (-24...0...+24 semitones)

127

127

--

--

RPN Null

This sets RPN and NRPN numbers to an unset
state. Internal data is not affected.

Controller

Value

Pitch bend change

±0 (center)

Channel pressure

0 (off)

Polyphonic key pressure

0 (off)

Modulation

0 (off)

Expression

127 (maximum)

Hold

0 (off)

Portamento

0 (off)

Sostenuto

0 (off)

Soft pedal

0 (off)

Portamento control

Reset the portamento source note number that was received

RPN

Number unset, internal data is not affected.

NRPN

Number unset, internal data is not affected.

Advertising