34

This projector has two indicators, each of which shows the operation condition of the projector.
Refer to Troubleshooting for additional indication signals.

Normal conditions

Abnormal conditions

*1: When LAMP MODE of the SETUP menu is set to CINEMA. When it is set to BRIGHT, this duration will be decreased.

*2: When LAMP MODE is set to BRIGHT, this duration will be decreased to 2000 hours.

POWER

STATUS

CONDITION

NOTE

Steady red

Off

Stand-by.

Steady green

Blinking green

Warming up period (about 1 minute).

The STANDBY/ON button cannot be used
until the STATUS indicator is steady green.

Steady green

Steady green

The projector is ready.

Steady red

Blinking green

Cooling down period (lasts under 2 minutes; normal when
shutting down).

Do not unplug the projector until the
STATUS indicator is off.

POWER

STATUS

CONDITION

SOLUTION

Steady green

or

Steady red

Blinking orange

Abnormal temperature

• The ventilation grilles are clogged with dust or dirt.

• The room temperature is high.

• Clean the ventilation grilles.

• Relocate the projector to a cooler place.

• Remove any objects blocking the

ventilation grilles.

Steady red

Blinking green

Abnormal when it occurs except while shutting down. The
protection circuit is working or the lamp is in an abnormal
condition.

• Wait until the STATUS indicator goes out,

then press the STANDBY/ON button.

• If the above solution is not effective,

replace the lamp.

Steady green

Blinking green/red

Lamp operation time warning. (Total lamp operation time

reached 3000 hours

*1

while the power was on.)

Replace the lamp.
Change with a new lamp if this problem
recurs.

Steady red

Blinking red

Lamp operation time warning. (Total lamp operation time

reached 3000 hours

*1

while the power was off.)

Steady red

Steady red

Lamp operation time warning. (Total lamp operation time

reached 4000 hours

*1, *2

while the power was off.)

Blinking

green/red

Off

The lamp cover isn’t closed.

Close the cover correctly.

Blinking

green/red

Steady or Blinking

Abnormal.

Contact your dealer.