GEQ function

170

PM5D/PM5D-RH V2 / DSP5D Owner’s Manual

Reference section

In this screen you can make settings for Waves Y96K plug-
in DSP cards installed in slots 1–4. For details on opera-
tion, refer to the Y96K operating manual.

Please note that Y96K cards will operate as follows.

• Settings will be stored/recalled as scene data, but the

Undo function is not supported.

• If you power the PM5D off and then on again, the con-

ventional scene data will be in the state of when the
power was turned off, but the Y96K will be in the state
that was last stored or recalled.

• If you recall a scene that produces a major change in

the Y96K’s settings, the Y96K’s settings will change sev-
eral seconds after recall occurs on the PM5D. If you
want to match this timing, set the appropriate START
OFFSET in the FADE TIME screen.

• Do not execute scene store or recall operations while

the screen indicates that the Y96K is waiting to update.
If you do so, the screen will become inoperable for up
to 30 seconds.

• The Y96K’s settings will be saved in the PM5D when

you store the scene. If in the past you had stored a
scene with a Y96K installed, and you then once again
store that scene without the Y96K installed, the previ-
ous Y96K settings will remain. If there is a scene for
which a Y96K has never been installed, and you install
a Y96K and then recall that scene, nothing will be
reflected in the Y96K.

• In PREVIEW mode, the PLUG-IN screen will not show

the state of the Y96K.

Note

The DSP5D does not support the Y96K.

GEQ function

Here you can adjust the boost/cut for a 31-band graphic
EQ or 8-band parametric EQ, specify the input/output
patching, and assign a GEQ to faders.

A Module select

This selects the GEQ module to operate. To switch
between modules, place the cursor here and turn the
[DATA] encoder, or click the / buttons at left or
right.

B LINK button

This button links adjacent odd-numbered

→ even-

numbered graphic EQ modules. When you turn this
button on, a window will appear, allowing you to select
whether the parameters will be copied from one mod-
ule to the other, or whether both modules will be
initialized.

PLUG-IN screen

PLUG-IN

GEQ PARAM (GEQ parameter) screen

GEQ PARAM

GEQ PARAM

1

5

6 7

2

4

3

Advertising