MIDI Data Format

376

PM5D/PM5D-RH V2 / DSP5D Owner’s Manual

Reference section

4.10 Level Meter Data – Parameter change –

4.10.1 Format

(Parameter change)

Once a Level Meter Request is received to enable transmission, the specified
meter data will be transmitted at 50 msec intervals for a duration of ten seconds.
If you want meter data to be transmitted continuously, you must transmit a
Request at intervals of no longer than ten seconds.

Reception
This message is echoed if [Parameter change ECHO] is ON.

Transmission
Once transmission is enabled by a Request, the meter data specified in the
Address will be transmitted on the [Rx CH] channel at a specific interval for a
specific duration. (The transmission interval and the duration of transmission
will differ between models of device.)
Transmission is disabled when the power is cycled, or when PORT settings are
changed.
If [Parameter change ECHO] is ON, the message is transmitted without change.

4.10.2 Format

(Parameter request)

Reception
This message is received if [Parameter change RX] is ON and [Rx CH] matches
the Device number included in the SUB STATUS. This message is echoed if
[Parameter change ECHO] is ON.
When this is received, the meter data specified in the Address is transmitted on
the [Rx CH] channel at a specific interval for a specific duration.
If this is received with an Address UL = 0x7F, transmission of all meter data will
stop (will be disabled) immediately.

Transmission
If [Parameter change ECHO] is ON, the message is transmitted without change.

4.11 Time Counter Data – Time Code –

4.11.1 Format

(Parameter change)

When transmission is enabled by receiving a Remote Time Counter request,
Time Counter data is transmitted at 50 ms intervals for a duration of ten
seconds. If you want counter data to be transmitted continuously, you must
transmit a Request at intervals of no longer than ten seconds.

Reception
This message is echoed if [Parameter change ECHO] is ON.

Transmission
When transmission is enabled by a request, Time Counter data is transmitted
for a specific duration.
Transmission is disabled when the power is cycled, or when PORT settings are
changed.
If [Parameter change ECHO] is ON, the message is transmitted without change.

4.11.2 Format

(Parameter request)

Reception
This message is received if [Parameter change RX] is ON and [Rx CH] matches
the Device number included in the SUB STATUS. This message is echoed if
[Parameter change ECHO] is ON.
When this message is received, Time Counter data is transmitted on the [Rx
CH] channel for a specific duration.
If a message is received with 0x7F as the second byte of the Address, data
transmission will be stopped (disabled) immediately.

Transmission
If [Parameter change ECHO] is ON, the message is transmitted without change.

STATUS

11110000 F0

System exclusive message

ID No.

01000011 43

Manufacture’s ID number (YAMAHA)

SUB STATUS

0001nnnn 1n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110 3E

Digital mixer

MODEL ID

00001111 0F

PM5D

DATA
CATEGORY

00100001 21

REMOTE LEVEL METER

DATA

0mmmmmmm mm

ADDRESS UL

0mmmmmmm mm

ADDRESS LU

0mmmmmmm mm

ADDRESS LL

0ddddddd dd

Data1 H

0ddddddd dd

Data1 L

:

:

EOX

11110111 F7

End of exclusive

STATUS

11110000 F0

System exclusive message

ID No.

01000011 43

Manufacture’s ID number (YAMAHA)

SUB STATUS

0011nnnn 3n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110 3E

Digital mixer

MODEL ID

00001111 0F

PM5D

DATA
CATEGORY

00100001 21

REMOTE LEVEL METER

DATA

0mmmmmmm mm

ADDRESS UL

0mmmmmmm mm

ADDRESS LU

0mmmmmmm mm

ADDRESS LL

0ccccccc ch

Request Ch Total Number H

0ccccccc cl

Request Ch Total Number L

EOX

11110111 F7

End of exclusive

STATUS

11110000 F0

System exclusive message

ID No.

01000011 43

Manufacture’s ID number (YAMAHA)

SUB STATUS

0001nnnn 1n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110 3E

Digital mixer

MODEL ID

00001111 0F

PM5D

DATA
CATEGORY

00101011 2b

Time Counter TC

DATA

0ddddddd dd

Hour

0ddddddd dd

Minute

0ddddddd dd

Second

0ddddddd dd

Frame

EOX

11110111 F7

End of exclusive

STATUS

11110000 F0

System exclusive message

ID No.

01000011 43

Manufacture’s ID number (YAMAHA)

SUB STATUS

0011nnnn 3n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110 3E

Digital mixer

MODEL ID

00001111 0F

PM5D

DATA
CATEGORY

00101011 2b

Time Counter TC

DATA

0ddddddd dd

0: Request transmission
0x7F: Request stop transmission

EOX

11110111 F7

End of exclusive

Advertising