PM5D/PM5D-RH V2 / DSP5D Owner’s Manual

Operating section

93

10

Scene memor

y

Other parameters

A DCA/GEQ/EFFECT

These buttons specify whether DCA groups, GEQ
modules, and internal effects will be excluded from (or
subject to) Recall.

Note

DCA groups provide a WITH NAME button. This button
excludes the DCA group name from the recall operation (or
selects it as the object of recall).

B MUTE MASTER

This button specifies whether the Mute Master key on/
off status will be excluded from (or subject to) Recall.

C MIDI REMOTE (PM5D only)

These buttons specify whether MIDI remote layers A–
D will be excluded from (or subject to) Recall.

D PLUG-IN (PM5D only)

These buttons specify whether the Waves plug-in DSP
cards Y96K installed in slots 1–4 will be excluded from
(or subject to) Recall.

E SET ALL

This button turns on all buttons for parameters

1

4

.

F CLEAR ALL

This button turns off all buttons for parameters

1

4

.

4

In the upper left of the screen, switch the
SELECTIVE RECALL ENABLED/DISABLED but-
ton to ENABLED.
When this button is set to ENABLED, the Selective
Recall function will apply to subsequently-stored
scenes.

5

Store the current scene.
The settings of the SELECTIVE RECALL screen will be
saved as part of the scene. When you recall this scene,
only the selected channels/parameters will be excluded
from (or subject to) Recall.

Note

• If you edit the settings of the SELECTIVE RECALL screen,

you must store that scene in order to make your changes
effective.

• Recall Safe and Selective Recall can be used together.

Channels/parameters excluded from recall operations by
either Recall Safe or Selective Recall (or both) will not be
recalled.