Using the Recall Safe function

“Recall Safe” is a function that excludes only specific parameters/channels from Recall operations. This differs from the Selec-
tive Recall settings (

p.92) made for individual scenes in that Recall Safe settings are common to all scenes.

1

In the DISPLAY ACCESS section, press the
[SCENE] key several times to access the
RECALL SAFE screen shown below.

2

Use the buttons in the screen to select the
parameters/channels that will be excluded
from Recall operations.
The function of the buttons in the screen and the pro-
cedures are the same as in the SELECTIVE RECALL
screen (when SAFE PARAMETER mode is selected),
except for the fact that HA (Head Amp) SAFE ON/
OFF button is added as a parameter in the INPUT
SAFE PARAMETER area.
The [RCL SAFE] indicator of the channel strip will
light for input channels, STEREO A/B channels, and
DCA groups for which Recall Safe is turned on.

Hint

• In the RECALL SAFE screen, clicking the parameter matrix

grid will display a “

” symbol with a “G” character in the

center. This “G” indicates that the setting is global, and
applies to all scenes.

• If desired, you can copy and paste Selective Recall settings

from the currently selected scene into the RECALL SAFE
screen (

p.183).

• If you scroll the scroll bar downward, you will see that the

CH column of the SAFE PARAMETERS area shows not
only input channels but also input ports. If you set the HA of
a certain input port to Recall Safe, the HA of the correspond-
ing channel will also be set to Recall Safe. Even if they are
assigned to multiple channels, the HA Recall Safe settings
for corresponding input ports/channels will be linked.

• If necessary, you can turn on the HA+CH button in the

SAFE KEY MODE SELECT area, so that when recall safe is
turned on/off using the panel [RECALL SAFE] key or the
RECALL SAFE button in the CH VIEW screen (INPUT
VIEW function), recall safe will be also be turned on/off for
the HA patched to the corresponding channel.

• Separately from the conventional Recall Safe functionality,

the OUTPUT ISOLATION field allows you to specify output
channels and parameters excluded from recall to be memo-
rized in SETUP memory (which is not subject to memory
card load operations) (

p.182).

3

If you want to use the panel to switch Recall
Safe on/off for a channel, use the [SEL] key to
select a channel and then press the SELECTED
CHANNEL section [RECALL SAFE] key to make
the key LED light.
Recall Safe will be turned on for the corresponding
channel.

Note

By default, ALL is selected as the parameters that will be
excluded from recall. This means that if you turn on Recall
Safe from the panel, the Recall Safe setting will affect all
parameters of the channel(s) for which it is turned on.

After you have finished making Recall Safe settings and
you recall a scene, only the selected channels/parame-
ters will be excluded from the Recall operation.

Note

Recall Safe and Selective Recall can be used together. Chan-
nels/parameters excluded from recall operations by either
Recall Safe or Selective Recall (or both) will not be recalled.

RECALL SAFE