279104-YTG-B-0307

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

TECHNICAL GUIDE

SPLIT-SYSTEM HEAT PUMPS

10 SEER – R-22

MODELS:

E*RA036 THRU 060
(3 THRU 5 NOMINAL TONS, 3 PH)

MODELS: 036-048 (3 PH)

MODELS: 060, 090 (3 PH)

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at
www.ari.org/aridirectory.

LISTED

ISO 9001

Certified Quality

Management System

DESCRIPTION

The 10 SEER Series heat pumps is the outdoor part of a ver-
satile system of heat pumps. It is designed to be custom-
matched with one of UPG’s complete line of evaporator sec-
tions, with each serving a specific function. Matching Air Han-
dlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-On coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.

WARRANTY

1-year limited parts warranty.
5-year limited compressor warranty.

FEATURES

QUALITY COILS - The coil is constructed of copper tube

and aluminum fins.

COIL PROTECTION - Coils are protected from damage by

a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.

PROTECTED COMPRESSOR - The compressor is inter-

nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.

DURABLE FINISH - Cabinet is made of pre-painted steel.

The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.

LOWER INSTALLED COST - Installation time and costs

are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.

TOP DISCHARGE - The warm air from the top mounted

fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.

LOW OPERATING SOUND LEVEL - The upward air flow

carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and com-
pressor operating sounds.

LOW MAINTENANCE - Long life permanently lubricated

motor-bearings need no annual servicing.

EASY SERVICE ACCESS - Fully exposed refrigerant con-

nections, a single panel covering the electrical controls,
and the molex plug in the control box connecting the con-
denser fan make for easy servicing of the unit.

SECURED SERVICE VALVES - Secured re-usable ser-

vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.

U.L. and C.U.L. listed - approved for outdoor application.

Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.