Konica Minolta CA-100Plus User Manual

Crt color analyzer, Cm y k, Dimensions

Advertising
background image

CRT COLOR ANALYZER

Dimensions

340

21

6

12

7

11

0

17

70

14

2

2

m

/5

m

47

.4

φ

60

30.2

φ

44

IS

O

5

m

m

sc

re

w

(d

ep

th

:6

m

m

)

60

φ

45

(Units : mm)

Receptor
Display range

Luminance
Chromaticity

*1 The chromaticity and luminance are measured under Konica Minolta’s condition (standard CRT (6500 K) is used).
*2 The luminance for monochrome is measured when the reading of luminance for white is 40.00 cd/m

2

.

*3 Measuring probe connected to probe connector P1 only,used USB (used RS-232C Baud rate: 38400 bps)
*4 At the CA-200 mode

Select the probe among the four types.

Specifications are subject to change without notice.

Specifications

Detector : Silicon photo cell

0.05 to 1000 cd/m

2

±2 %±1 digit of reading (temperature : 23°C±2°C, relative humidity : (40±10)%)

0.05 to 1000 cd/m

2

xyLv, T

∆uvLv, RGB, XYZ, u'v'Lv

∆x, ∆y, ∆Lv, R/G, B/G, ∆G, ∆R, B/R, G/R

NTSC, PAL, EXT, UNIV, INT
Vertical syncronizing frequency : 40 to 200 Hz
100 channels
Standard function

0 to 28

°C : relative humidity 70 % or less with no condensation

28 to 40

°C : relative humidity 40 % or less with no condensation

100-240 V ~, 50-60 Hz 50 VA
340

Ч 127 Ч 216 mm (W × H × D), φ45 × 142 mm

3.58 kg, 285 g

0.01 to 1000 cd/m

2

Displayed in 4 or 3-digit value (Can be chosen)

0.05 to 1000 cd/m

2

0.2 %+1 digit (2

σ)

0.05 to 0.19 cd/m

2

±0.006 (for white)

0.20 to 0.49 cd/m

2

±0.004 (for white)

0.50 to 1000 cd/m

2

±0.003 (for white)

40.00 cd/m

2

±0.002 (for white), ±0.004 (for monochrome)*2

0.05 to 0.19 cd/m

2

0.006 (2

σ)

0.20 to 0.49 cd/m

2

0.002 (2

σ)

0.50 to 1000 cd/m

2

0.001 (2

σ)

0.05 to 0.99 cd/m

2

5 measurements/sec. (4.5 measurements / sec.)*4

1.00 to 1000 cd/m

2

20 measurements/sec. (17 measurements / sec.)*4

USB (1.1 conformity) , RS-232C (38,400 bps or below)
Max. 5 points (Use 4-Probe Expansion Board CA-B04)
Temperature : 10 to 28

°C; relative humidity 70 % or less with no condensation

Luminance change :

±2 % ±1 digit of reading for white

Chromaticity change :

±0.002 for white, ±0.006 for monochrome

from reading of Konica Minolta's standard CRT*1, 40.00 cd/m

2

, with 23

°C 40 %

0.05 to 2000 cd/m

2

0.05 to 2000 cd/m

2

0.01 to 2000 cd/m

2

0.05 to 2000 cd/m

2

0.2 %+1 digit (2

σ)

0.05 to 0.09 cd/m

2

±0.008 (for white)

0.10 to 0.39 cd/m

2

±0.006 (for white)

0.40 to 0.99 cd/m

2

±0.004 (for white)

1.00 to 2000 cd/m

2

±0.003 (for white)

40.00 cd/m

2

±0.002 (for white), ±0.004 (for monochrome)*2

0.05 to 0.09 cd/m

2

0.009 (2

σ)

0.10 to 0.39 cd/m

2

0.006 (2

σ)

0.40 to 0.99 cd/m

2

0.002 (2

σ)

1.00 to 2000 cd/m

2

0.001 (2

σ)

0.05 to 1.99 cd/m

2

5 measurements/sec. (4.5 measurements / sec.)*4

2.00 to 2000 cd/m

2

20 measurements/sec. (17 measurements / sec.)*4

Mac OS 10.3.7J Adobe Illustrator10J

2006.11.15

C

M

Y

K

System Diagram

Measuring Probe (2 m) CA-P02
Measuring Probe (5 m) CA-P05
High luminance Measuring Probe (2 m) CA-PH02
High luminance Measuring Probe (5 m) CA-PH05

(Optional)

PC (Commercially available)

PC-AT compatible

CA-100Plus

AC Power Cord (Standard)

PC Software for Color Analyzer

CA-SDK (Standard)

4-Probe Expansion Board

CA-B04

(Optional)

Multi-Probe

Measuring Probe Holder

CA-A11 (Standard)

CA-100Plus(Measuring Probe 2 m or 5 m)

CA-100Plus(High luminance Measuring Probe 2 m or 5 m)

Measuring Probe (2 m) CA-P02
Measuring Probe (5 m) CA-P05
High luminance Measuring Probe (2 m) CA-PH02
High luminance Measuring Probe (5 m) CA-PH05

Luminance

Measurement range
Accuracy (for white)*1
Repeatability *1

Chromaticity

Measurement range
Accuracy *1

Repeatability *1

Measurement speed

xyLv

Display

Digital
Analog

SYNC mode
Object under measurement
Memory channel
Analyzer function
Interface
Multi-point Measurement
Operating temperature/humidity range

Storage temperature/humidity range

Input voltage range
Size

Mainbody, Probe

Weight

Mainbody, Probe

Type 1:Helvetica,Helvetica-Bold,Helvetica-BoldOblique,Symbol,TimesNewRomanPS-ItalicMT,ZapfDingbats

CRT

(temperature : 23

°C±2°C,

relative humidity : (40

±10)%)

*3

AGMEPK

Printed in Japan

9242-4885-12

©2003 KONICA MINOLTA SENSING, INC.

SAFETY PRECAUTIONS

9

For correct use and for your safety, be sure to read
the instruction manual before using the instrument.

Always connect the instrument to the
specified power supply voltage.
Improper connection may cause a fire
or electric shock.

Certificate No : JQA-E-80027

Registration Date : March 12, 1997

Certificate No : YKA 0937154

Registration Date : March 3, 1995

Advertising