Troubleshooting – Pioneer PDK-50HW3 User Manual

Page 11

Advertising
background image

24

En

TROUBLESHOOTING

Incorrect operations are often mistaken for trouble and malfunctions. If you think there is something wrong
with this component, check the points below. Sometimes the trouble may originate from another
component. Thus, also check the other electrical appliances also in use.
If the trouble cannot be rectified even after checking the following items, contact your dealer or nearest
PIONEER service center.

Symptom

No power

No response when operated.

USB cable is not recognized by
computer when connected.

Cursor position is far from that
of pen tip on screen.

C u r s o r p o s i t i o n d i v e r g e s
slightly from that of pen tip on
screen.

Cursor position diverges from
pen after initial setting.

The special dedicated pen does
not respond.

Cause

÷ USB cable is disconnected from

computer.

÷ Computer power is not turned on.

÷ USB cable is disconnected.

÷ USB port may not be operating

due to some problem with com-
puter or Windows operating sys-
tem.

÷ A screen resolution other than

1280x768 is being used. Or
resolution has been changed.

÷ The plasma display's screen

display size setting has been
changed.

÷ Driver software is not installed

properly.

÷ The plasma display's screen

display position has shifted.

÷ The plasma display's AUTO SET

UP screen position adjustment
has been reset.

÷ Plasma display's [MASK CON-

TROL] or [ORBITER] is set to
[ON].

÷ Battery is depleted.

÷ Insufficient pen tip pressure is

being used so that the pen tip
switch doesn't turn on.

÷ The holes in rear end of pen are

blocked.

÷ The pen is being used outside of

its effective range.

÷ The unit is receiving ultrasonic

influence from other device.

÷ You are wearing gloves while

holding the pen (pen's ultrasonic
signals are being absorbed).

÷ Driver software is not installed

properly.

Solution

÷ Connect USB cable to computer

correctly.

÷ Turn on power to computer.

÷ Connect USB cable correctly.

÷ Consult computer manufacturer

for BIOS and driver software up-
dates where applicable.

÷ Change the driver software

settings as required.

÷ Install driver software correctly.

÷ Use the plasma display's calibra-

tion mode to adjust the vertical
and horizontal position.

÷ Depending on the image, slight

divergences can be manually cor-
rected.

÷ Set [MASK CONTROL], [OR-

BITER] to [OFF].

÷ Check the LED indicator, and if it

does not light brightly, replace
battery.

÷ Press the tip to the screen with

sufficient pressure to turn on the
pen tip switch.

÷ Do not cover the holes in rear

end of pen.

÷ Use only within the proper

onscreen usage range.

÷ Do not place any device near the

u n i t t h a t i s s u e s u l t r a s o n i c
waves.

÷ Remove gloves.

÷ Install driver software correctly.

Advertising