Cz`<<`.hc ēăăêńńêēĉêĉö, Commissioning, Shutting down – STIEBEL ELTRON SBB WP SOL с 12.05.2008 User Manual

Page 19: Troubleshooting, 5 fitting the thermometer and dhw sensor, 1 appliance handover, 1 fault table

Advertising
background image

EN

GL

ISH

ŷŷŷĪńŒê¼¼ùé¼ùŒļĒĉĪ›Ēă

Z ŗƃĜéÑƃĜ qT ZH<’

ĜĎ

.CZ`<<`.HC

ĒăăêńńêĒĉêĉÖ

2

6

_0

2_0

9

_00

3

5

1

2

1 Cold water connection
2 Cold water inlet pipe
f Connect the cold water supply directly to the cylinder or with

the connecting pipe routed between the cylinder feet.

f During fitting, counterhold the fitting with an open-ended

spanner (size 36).

f Check the rigidity of the connecting pipe and secure it further

if required.

f Size the drain so that water can drain off unimpeded when

the safety valve is fully opened. The blow-off aperture of the
safety valve must remain open to the atmosphere.

f Fit the blow-off line of the safety assembly with a constant

slope.

f Observe the information in the installation instructions of the

safety assembly.

9.5

Fitting the thermometer and DHW sensor

2

6

_0

3_

2

0_0

0

0

5

1

1 Thermometer
f Insert the thermometer as far as it will go and align it.
f Insert the DHW sensor as far as it will go into the well for the

heat pump flow sensor (recommended energy saving posi-
tion) or heat pump return sensor (high DHW convenience).

10. Commissioning

f Open a downstream draw-off point until the appliance has

filled up and the pipes are free of air.

f Vent the indirect coils after filling the heat pump system.
f Fit the accessories and check them if necessary.
f Check the function of the safety valve.
f Check that the DHW temperature on the heat pump control

unit is displayed correctly.

10.1 Appliance

handover

f Explain the appliance function to users and familiarise them

with its operation.

f Make users aware of potential dangers, especially the risk of

scalding.

f Hand over these instructions.

11. Shutting down

f Disconnect the appliance from the mains at the MCB/fuse in

the fuse box.

f Drain the appliance. See chapter “Maintenance / Draining the

appliance”.

12. Troubleshooting

12.1 Fault

table

%|şùŒ

|şń¼

V¼ă¼®ź

The safety valve drips
when the heating is
switched off.

The valve seat is con-
taminated.

Clean the valve seat.

Advertising