TIMBERK THU UL 07 series User Manual

Page 6

Advertising
background image

Difference between the

level of current humidity

and readings of a

humidity recorder

is too big

Dirt accumulation

inside an air vent

Clean the air vent. Even in one room humidity

can be different depending on the location

The unit is operated in

places, where it is affected

by the environment,

for example, by a window

Install the unit in places, where it cannot be

affected by the environment

Steam has an

unpleasant odor

Not fresh water in use
There are remains of

not fresh water or litter

in the water groove

Clean the unit in accordance with the cleaning

and maintenance manual and fill it with fresh

water

Poor atomizing

(insufficient

performance)

Remedy

Defect

Possible cause

The unit is operating in

a light mode (low

atomizing frequency)

No defect. If necessary to switch to the intensive

mode, press Steam button in

the manual setting mode and switch the unit

to the intensive operation mode.

Atomizer is clogged

Clean the atomizer

Tank water temperature

is too low

Set the maximum performance. Humidifier s

performance will be increased in 10 minutes

No atomizing

The plug is poorly

inserted into an outlet

Connect the plug into an outlet carefully

Red light on the water

indicator has illuminated

and went out (water

tank is completely empty)

Add water to the tank

A white residue appeared

on objects around the

humidifier (salts,

separating from water)

Lime deposits are formed

on the membrane

Clean the humidifiers membrane by a special brush

Water demineralization

cartridge is worn down

(ion exchange resin)

Replace the filter cartridge

Table 2.

IMPORTANT!
Useful capacity of an ion exchange filter is about 400 liters. Continuous
use after expiration reduces the capability to filter hard components
(calcium and magnesium) of tap water. As a result, the level of white
residue formation increases.
Standard filter replacement period is about 180 days given the
automatic operation mode (duration of humidification with heating
about 6 hours every day). Filter replacement period can be decreased
depending on different frequency of operation and water quality. Pay
attention to the formation of a white powder.

It is recommended to use softened water from a domestic filter to reduce
salification inside the device

9. CLEANING AND MAINTENANCE OF THE UNIT
Prior to cleaning make sure that the plug is disconnected from an outlet.
Otherwise it may result in an electric shock. Before cleaning, wait until water
in grooves is completely cooled down in order not to burn hands.
8.1 To wipe the external surface of the unit use a damp and soft cloth. To
prevent an electric shock do not scratch and do not damage unit s elements
upon cleaning.
When cleaning the unit, do not use solvents, benzine, dimethylbenzene, hard
brush, talc powder and other substances other than water.
8.2 Wipe water remains inside the groove under the tank by a damp and soft
cloth. To remove water remains on small parts you can use the brush, and
then wipe them again with a soft cloth. Clean the unit once or twice a week.
8.3 If there is dirt on the membrane, clean it by means of a brush. Clean the
unit once or twice a week.
8.4 Use a brush to remove water remains on the surface of the nozzle and
then wipe it again by a soft cloth. Clean the unit once or twice a week.
8.5 Clean the water tank and the atomizer by pure water. Clean the cap
carefully, without applying much effort, otherwise it may result in water
leakage through the cap.
Once water remains are removed from the surface of the atomizer, wipe it by
a soft cloth. Clean the external surface of the unit by a damp and soft cloth.

6

10. TROUBLESHOOTING
In case of emergencies resort to troubleshooting methods, given in tables.

www.timberk.com electric humidifier

11. UTILIZATION
If you are unable to solve issues by means of mentioned methods, contact
a service center.Life of the humidifier is 2 years.
Upon expiration of the humidifier it must be disposed in accordance with
regulations, rules and by means, currently in force at a disposal station.

The used water has a

hight content of calcium

and magnesium

Use softened water from domenic filter

Advertising