ENGLISH

Video output connectors [VIDEO1, VIDEO2]

The video signals from the camera after cable
compensation are output from these connectors. (The
same signal is output from connectors 1 and 2.)
Connect the connectors to the video input connectors
on the live switcher, colour monitor, VTR or other device.
(Output impedance: 75 ohms)

SYNC output connector [SYNC]

The composite sync signal is output from this connector.
Connect the connector to the gen-lock input connector on
the colour monitor or other device.
(Output impedance: 75 ohms)

RGB/Y, PR and PB/YC output connectors

[R/PR/C, G/Y/Y, B/PB]

If a camera such as the AW-E650 with RGB/Y, PR and
PB/YC signal output facilities is connected to the remote
control unit, its signals are output from these connectors.
(Output impedance: 75 ohms)
The RGB/Y, PR or PB/YC signals are selected using
the camera’s menu. (For details, refer to the camera’s
operating instructions.)

S-Video output connector [S-VIDEO OUT]

(4-pin S-connector)

The same signals as the ones output from the R/PR/C
and G/Y/Y connectors among the RGB/Y, PR and PB/YC
output connectors  are output from this connector.
(Output impedance: 75 ohms)
The YC signals are selected using the camera’s menu,
and connected to a colour monitor or other device
equipped with an S-Video input connector.

Note:
When the RGB/Y, PR and PB/YC output connectors 
and S-Video output connector  are used at the same
time, the level of the output signals will be reduced.
Therefore, use either connectors  or connector  in
line with the connectors used on the device connected to
the remote control unit.

Tally/intercom input/output connector

[TALLY/INCOM] (D-SUB 15-pin connector)

Connect this to the TALLY & INCOM connector on the live
switcher (AW-SW350).
Set the INCOM selector switch on the live switcher
(AW-SW350) to [3-wire type].
When inputting the tally control signals from another
device, input them with 0 V for ON and open for OFF.

Pin No.

Signal Name

1

TALLY

6

INCOM MIC

7

INCOM GND

8

INCOM SP

11

TALLY GND

Fuse holder [FUSE]

Fuse used: HT1AN5 (AC 250 V, 1 A)

AC power socket [AC IN]

Attach one end of the power cord provided to this socket
and the other end to the AC 220 to 240 V (50 Hz) power
supply.